135N9157
Danfoss 135N9157 - VLT HVAC Drive FC 102 (37 kW / 50 HP, IP20, 525-690V)
- Frequency Converter
- VLT® HVAC Drive FC-102
- (P37K) 37 KW / 50 HP, Specific Ratings: 30kW@525-550V, 40HP@575V, 37kW@690V
- Three phase, 525 - 690 VAC *,(E20) IP20 / Chassis
- RFI class A1 (C2)
- Brake chopper + Safe stop
- Graphical Loc. Cont. Panel
- Coated PCB, Loadsharing
- Latest release std. SW.
- Frame: B4
- No A Option, No B Option
- No C1 option, No D option
Model code:
FC-102P37KT7E20H4UGCDXXSXXXXAXBXCXXXXDX
FC-102P37KT7E20H4UGCDXXSXXXXAXBXCXXXXDX
Similar products
- Genuine Danfoss products
- Danfoss manufacturer warranty
- Reply within one business day
Product details
| Product Group | FC- | VLT® HVAC Drive FC- |
| Series | 102 | |
| Power Rating | P37K | (P37K) 37 KW / 50 HP |
| Phase | T | Three phase |
| Mains Voltage | 7 | 525 - 690 VAC * |
| Enclosure | E20 | (E20) IP20 / Chassis |
| RFI Filter | H4 | RFI class A1 (C2) |
| Brake - Safe Stop | U | Brake chopper + Safe stop |
| LCP | G | Graphical Loc. Cont. Panel |
| Coating PCB | C | Coated PCB |
| Mains Option | D | Loadsharing |
| Adaptation A | X | Standard Cable Entries |
| Adaptation B | X | No adaptation |
| Software Release | SXXX | Latest release std. SW. |
| Software Language Pack | X | Standard Language Pack |
| A Option | AX | No A Option |
| B Option | BX | No B Option |
| C0 Option MCO | CX | No C0 option |
| C1 Option | X | No C1 option |
| C Option Software | XX | No software option |
| D Option | DX | No D option |
| Frame Size | B4 | |
| Power 110% (NO) [KW] | 37 | |
| Height [mm] | 516,0 | |
| Width w/ no C options [mm] | 229,0 | |
| Depth [mm] | 242,0 | |
| Depth with Option A/B [mm] | 242,0 | |
| kVA | 49 | |
| Power Loss NO [W] | 592 | |
| Continuous Current (NO) [A] | 43 | |
| Intermittent Current (NO) [A] | 47.3 | |
| Continuous Current (NO) [A] | 41 | |
| Intermittent Current (NO) [A] | 45.1 | |
| Power Rating at 525-550V | 30kW | |
| Power Rating at 575V | 40HP | |
| Power Rating at 690V | 37kW |
Technical data
| Motor power | 37 kW / 50 HP | |
| Mains voltage | 525 - 690 VAC * | |
| Phase | Three-phase | |
| Protection rating | IP20 / Chassis | |
| Frame size | B4 | |
| RFI filter | Class A1 (EMC C2) | |
| Brake chopper | Yes | |
| Safe Torque Off | Yes | |
| Control panel | Graphical LCP | |
| PCB coating | Coated PCB | |
| Mains option | Loadsharing | |
| Fieldbus | None | |
| Product type | Frequency converter | |
| Continuous output current | 43 A | |
| Continuous current (high line) | 41 A | |
| Intermittent output current | 47.3 A | |
| Apparent power | 49 kVA | |
| Power loss | 592 W | |
| Power, normal overload | 37 kW | |
| Height | 516 mm | |
| Width | 229 mm | |
| Depth | 242 mm | |
| Depth with A/B options | 242 mm | |
| Net weight | 22.19 kg | |
| Gross weight | 25.89 kg | |
| Packed volume | 105.7 L | |
| EAN | 5710108253776 | |
| ECCN (EU) | Y901 | |
| ECCN (US) | 3A999.a | |
Documents
Operating guides, design guides, certificates and CAD drawings for 135N9157 are available on request. Ask for documents →
Other 37 kW / 50 HP variants in VLT HVAC Drive FC 102
- 136F8543 IP20 · Class A1 · B4
- 132H3500 IP20 · Class A1 · B4
- 136F8685 IP20 · Class A1 · B4
- 134X0670 IP20 · Class A1 · B4
- 134U4664 IP20 · Class A1 · B4
- 134U1009 IP20 · Class A1 · B4
- 134L6815 IP20 · Class A1 · B4
- 134U1008 IP20 · Class A1 · B4
- 136G0589 IP20 · Class A1 · B4
- 137N8803 IP20 · Class A2 · B4
- 137N8415 IP20 · Class A2 · B4
- 136G9245 IP20 · Class A2 · B4
- 134U3226 IP20 · Class A2 · B4
- 134L8443 IP20 · Class A2 · B4
- 134G4584 IP21 · Class A2 · C2
- 137X3495 IP21 · Class A2 · C2
- 134H6626 IP21 · Class A2 · C2
- 137H8053 IP21 · Class A2 · C2
- 134X8438 IP21 · Class A2 · C2
- 131Z1907 IP21 · Class A2 · C2
- 134G2864 IP21 · Class A2 · C2
- 131Z1200 IP21 · Class A1 · C2
- 131Z1505 IP21 · Class A1 · C2
- 134N7930 IP21 · Class A1 · C2