Danfoss VLT Refrigeration Drive FC 103 FC-103N132T4E54H2TGC3XXSXXXXAXBXCXXXXDX
135U3450

Danfoss 135U3450 - VLT Refrigeration Drive FC 103 (132 kW / 200 HP, IP54, 380-480V)

  • Frequency converter
  • VLT® Refrigeration Drive FC-103
  • (N132) 132 KW / 200 HP,
  • Three phase, 380 - 480 VAC, (E54) IP54 / Type 12
  • RFI filter Class A2
  • Safe Stop
  • Graphical Loc. Cont. Panel
  • Coated PCB, Mains Disconnect + Fuse
  • No adaptation
  • Latest release std. SW.
  • No A Option, No B Option
  • No C1 option, No D option
  • Frame: D5H
Model code:
FC-103N132T4E54H2TGC3XXSXXXXAXBXCXXXXDX
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® Refrigeration Drive
Series103
Power RatingN132(N132) 132 KW / 200 HP
PhaseTThree phase
Mains Voltage4380 - 480 VAC
EnclosureE54(E54) IP54 / Type 12
RFI FilterH2RFI filter Class A2
Brake - Safe StopTSafe Stop
LCPGGraphical Loc. Cont. Panel
Coating PCBCCoated PCB
Mains Option3Mains Disconnect + Fuse
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionAXNo A Option
B OptionBXNo B Option
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionDXNo D option
Frame SizeD5H
Power 110% (NO) [KW]132
kVA180
Power Loss NO [W]2949
Power Loss NO [W]2719
Continuous Current (NO) [A]260
Intermittent Current (NO) [A]286
Continuous Current (NO) [A]240
Intermittent Current (NO) [A]264
Height [mm]1324,0
Width w/ no C options [mm]325,0
Depth [mm]381,0
Depth with Option A/B [mm]381,0

Technical data

Motor power132 kW / 200 HP
Mains voltage380 - 480 VAC
PhaseThree-phase
Protection ratingIP54 / Type 12
Frame sizeD5H
RFI filterClass A2 (EMC C3)
Brake chopperNo
Safe Torque OffYes
Control panelGraphical LCP
PCB coatingCoated PCB
Mains optionMains Disconnect + Fuse
FieldbusNone
Product typeFrequency converter
Continuous output current260 A
Continuous current (high line)240 A
Intermittent output current286 A
Apparent power180 kVA
Power loss2949 W
Power, normal overload132 kW
Height1324 mm
Width325 mm
Depth381 mm
Depth with A/B options381 mm
Net weight166 kg
Gross weight166.3 kg
Packed volume587.7 L
EAN5710108296964
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 135U3450 are available on request. Ask for documents →

Other 132 kW / 200 HP variants in VLT Refrigeration Drive FC 103

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery

We only use your details to answer this request. See our privacy policy.