135U6801
Danfoss 135U6801 - VLT Refrigeration Drive FC 103 (500 kW / 650 HP, IP54, 380-480V)
- Frequency converter
- VLT® Refrigeration Drive FC-103
- (N500)500 KW / 650 HP,
- Three phase, 380 - 480 VAC,(E54) IP54 / Type 12
- RFI filter Class A2
- No brake chopper
- Graphical Loc. Cont. Panel
- Coated PCB, Mains Disconnect + Fuse
- Latest release std. SW.
- PROFIBUS DP MCA 101, No B Option
- No C1 option, 24V DC backup
- Frame: E2H
Model code:
FC-103N500T4E54H2XGC3XXSXXXXA0BXCXXXXD0
FC-103N500T4E54H2XGC3XXSXXXXA0BXCXXXXD0
Similar products
- Genuine Danfoss products
- Danfoss manufacturer warranty
- Reply within one business day
Product details
| Product Group | FC- | VLT® Refrigeration Drive |
| Series | 103 | |
| Power Rating | N500 | (N500)500 KW / 650 HP |
| Phase | T | Three phase |
| Mains Voltage | 4 | 380 - 480 VAC |
| Enclosure | E54 | (E54) IP54 / Type 12 |
| RFI Filter | H2 | RFI filter Class A2 |
| Brake - Safe Stop | X | No brake chopper |
| LCP | G | Graphical Loc. Cont. Panel |
| Coating PCB | C | Coated PCB |
| Mains Option | 3 | Mains Disconnect + Fuse |
| Adaptation A | X | Standard Cable Entries |
| Adaptation B | X | No adaptation |
| Software Release | SXXX | Latest release std. SW. |
| Software Language Pack | X | Standard Language Pack |
| A Option | A0 | PROFIBUS DP MCA 101 |
| B Option | BX | No B Option |
| C0 Option MCO | CX | No C0 option |
| C1 Option | X | No C1 option |
| C Option Software | XX | No software option |
| D Option | D0 | 24V DC backup |
| Frame Size | E2H | |
| Power 110% (NO) [KW] | 500 | |
| Height [mm] | 2000,0 | |
| Width w/ no C options [mm] | 700,0 | |
| Depth [mm] | 510,0 | |
| Depth with Option A/B [mm] | 510,0 | |
| kVA | 610 | |
| Power Loss NO [W] | 9473 | |
| Power Loss NO [W] | 7809 | |
| Continuous Current (NO) [A] | 880 | |
| Intermittent Current (NO) [A] | 968 | |
| Continuous Current (NO) [A] | 780 | |
| Intermittent Current (NO) [A] | 858 |
Technical data
| Motor power | 500 kW / 650 HP | |
| Mains voltage | 380 - 480 VAC | |
| Phase | Three-phase | |
| Protection rating | IP54 / Type 12 | |
| Frame size | E2H | |
| RFI filter | Class A2 (EMC C3) | |
| Brake chopper | No | |
| Control panel | Graphical LCP | |
| PCB coating | Coated PCB | |
| Mains option | Mains Disconnect + Fuse | |
| Fieldbus | PROFIBUS DP MCA 101 | |
| Product type | Frequency converter | |
| Continuous output current | 880 A | |
| Continuous current (high line) | 780 A | |
| Intermittent output current | 968 A | |
| Apparent power | 610 kVA | |
| Power loss | 9473 W | |
| Power, normal overload | 500 kW | |
| Height | 2000 mm | |
| Width | 700 mm | |
| Depth | 510 mm | |
| Depth with A/B options | 510 mm | |
| Net weight | 318 kg | |
| Gross weight | 318.3 kg | |
| EAN | 5710108330743 | |
| ECCN (EU) | Y901 | |
| ECCN (US) | 3A999.a | |
Documents
Operating guides, design guides, certificates and CAD drawings for 135U6801 are available on request. Ask for documents →
Other 500 kW / 650 HP variants in VLT Refrigeration Drive FC 103
- 132L0943 IP20 · Class A2 · E4H
- 132L0387 IP20 · Class A2 · E4H
- 136X2168 IP20 · Class A2 · E4H
- 137H2331 IP20 · Class A2 · E4H
- 167G8800 IP20 · Class A2 · E4H
- 167G3005 IP20 · Class A2 · E4H
- 136L0392 IP20 · Class A2 · E4H
- 136G2491 IP20 · Class A2 · E4H
- 137X7999 IP20 · Class A2 · E4H
- 167F5075 IP20 · Class A2 · E4H
- 135X5397 IP20 · Class A2 · E4H
- 135U6673 IP20 · Class A2 · E4H
- 137N0683 IP20 · Class A2 · E4H
- 136X0053 IP20 · Class A1 · E4H
- 167F8659 IP20 · Class A1 · E4H
- 132X1355 IP20 · Class A1 · E4H
- 136U0372 IP20 · Class A1 · E4H
- 136L9368 IP20 · Class A1 · E4H
- 136Z4051 IP20 · Class A1 · E4H
- 137L8744 IP21 · Class A2 · E2H
- 132N9420 IP21 · Class A2 · E2H
- 132X0990 IP21 · Class A2 · E2H
- 136H6458 IP54 · Class A2 · E2H
- 137X6295 IP54 · Class A2 · E2H