Danfoss VLT HVAC Drive FC 102 FC-102P560T4E21N4TGC3XXSXXXXAQB4CXXXXDX
135U9753

Danfoss 135U9753 - VLT HVAC Drive FC 102 (560 kW / 750 HP, IP21, 380-480V)

  • Frequency Converter
  • VLT® HVAC Drive FC-102
  • (P560) 560 KW / 750 HP, Three phase
  • 380 - 480 VAC, IP21 / Type 1
  • LHD - AAF006 filter + A1 RFI
  • Safe Stop
  • Graphical Loc. Cont. Panel
  • Coated PCB, Mains Disconnect + Fuse
  • Latest release std. SW.
  • Frame: F18
  • No C1 option, No D option
  • Modbus TCP MCA 122, MCB-114 VLT Sensor Input
Model code:
FC-102P560T4E21N4TGC3XXSXXXXAQB4CXXXXDX
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® HVAC Drive FC-
Series102
Power RatingP560(P560) 560 KW / 750 HP
PhaseTThree phase
Mains Voltage4380 - 480 VAC
EnclosureE21IP21 / Type 1
RFI FilterN4LHD - AAF006 filter + A1 RFI
Brake - Safe StopTSafe Stop
LCPGGraphical Loc. Cont. Panel
Coating PCBCCoated PCB
Mains Option3Mains Disconnect + Fuse
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionAQModbus TCP MCA 122
B OptionB4MCB-114 VLT Sensor Input
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionDXNo D option
Frame SizeF18
Power 110% (NO) [KW]560
Height [mm]2277,0
Width w/ no C options [mm]2802,0
Depth [mm]607,0
Depth with Option A/B [mm]607,0
kVA686
Power Loss NO [W]11822
Power Loss NO [W]10424
Continuous Current (NO) [A]990
Intermittent Current (NO) [A]1089
Continuous Current (NO) [A]890
Intermittent Current (NO) [A]979

Technical data

Motor power560 kW / 750 HP
Mains voltage380 - 480 VAC
PhaseThree-phase
Protection ratingIP21 / Type 1
Frame sizeF18
RFI filterClass A1 (EMC C2)
Brake chopperNo
Safe Torque OffYes
Control panelGraphical LCP
PCB coatingCoated PCB
Mains optionMains Disconnect + Fuse
FieldbusModbus TCP MCA 122
Product typeFrequency converter
Continuous output current990 A
Continuous current (high line)890 A
Intermittent output current1089 A
Apparent power686 kVA
Power loss11822 W
Power, normal overload560 kW
Height2277 mm
Width2802 mm
Depth607 mm
Depth with A/B options607 mm
Net weight1575 kg
Gross weight1915 kg
Packed volume0 L
EAN5710108360252
ECCN (US)3A999

Documents

Operating guides, design guides, certificates and CAD drawings for 135U9753 are available on request. Ask for documents →

Other 560 kW / 750 HP variants in VLT HVAC Drive FC 102

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery