Danfoss VLT HVAC Drive FC 102 FC-102N800T7E20H2TXC7XQSXXXXANB4CXRXXD0
135X2947

Danfoss 135X2947 - VLT HVAC Drive FC 102 (800 kW / 1200 HP, IP20, 525-690V)

  • Frequency Converter
  • VLT® HVAC Drive FC-102
  • (N800) 800 KW / 1200 HP, Specific Ratings: 670kW@525-550V, 950HP@575V, 800kW@690V
  • Three phase, 525 - 690 VAC *,(E20) IP20 / Chassis
  • RFI Filter
  • Safe Stop
  • No Loc. Cont. Panel
  • Coated PCB, Fuse
  • Latest release std. SW.
  • Frame: E4H
  • EtherNet/IP MCA 121, MCB-114 VLT Sensor Input
  • MCB-113 Ext. Relay Card, MCB-107 24V DC backup
Model code:
FC-102N800T7E20H2TXC7XQSXXXXANB4CXRXXD0
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® HVAC Drive FC-
Series102
Power RatingN800(N800) 800 KW / 1200 HP
PhaseTThree phase
Mains Voltage7525 - 690 VAC *
EnclosureE20(E20) IP20 / Chassis
RFI FilterH2RFI Filter
Brake - Safe StopTSafe Stop
LCPXNo Loc. Cont. Panel
Coating PCBCCoated PCB
Mains Option7Fuse
Adaptation AXStandard Cable Entries
Adaptation BQHeat-sink access
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionANEtherNet/IP MCA 121
B OptionB4MCB-114 VLT Sensor Input
C0 Option MCOCXNo C0 option
C1 OptionRMCB-113 Ext. Relay Card
C Option SoftwareXXNo software option
D OptionD0MCB-107 24V DC backup
Frame SizeE4H
Power 110% (NO) [KW]800
Height [mm]1578,0
Width w/ no C options [mm]607,0
Depth [mm]482,0
Depth with Option A/B [mm]482,0
kVA1016
Power Loss NO [W]12723
Power Loss NO [W]12321
Continuous Current (NO) [A]889
Intermittent Current (NO) [A]978
Continuous Current (NO) [A]850
Intermittent Current (NO) [A]935
Power Rating at 525-550V670kW
Power Rating at 575V950HP
Power Rating at 690V800kW

Technical data

Motor power800 kW / 1200 HP
Mains voltage525 - 690 VAC *
PhaseThree-phase
Protection ratingIP20 / Chassis
Frame sizeE4H
RFI filterClass A2 (EMC C3)
Brake chopperNo
Safe Torque OffYes
Control panelNone
PCB coatingCoated PCB
Mains optionIntegrated Fuse
FieldbusEtherNet/IP MCA 121
Product typeFrequency converter
Continuous output current889 A
Continuous current (high line)850 A
Intermittent output current978 A
Apparent power1016 kVA
Power loss12723 W
Power, normal overload800 kW
Height1578 mm
Width607 mm
Depth482 mm
Depth with A/B options482 mm
Net weight243 kg
Gross weight273 kg
EAN5710108392284
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 135X2947 are available on request. Ask for documents →

Other 800 kW / 1200 HP variants in VLT HVAC Drive FC 102

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery

We only use your details to answer this request. See our privacy policy.