Danfoss VLT HVAC Drive FC 102 FC-102N450T7E5MH2BGC7XQSXXXXANB4CXXXXD0
135X3447

Danfoss 135X3447 - VLT HVAC Drive FC 102 (450 kW / 600 HP, IP54, 525-690V)

  • Frequency Converter
  • VLT® HVAC Drive FC-102
  • (N450) 450 KW / 600 HP, Specific Ratings: 355kW@525-550V, 450HP@575V, 450kW@690V
  • Three phase, 525 - 690 VAC *,IP54/Type 12+main shield
  • RFI Filter
  • Brake chopper
  • Graphical Loc. Cont. Panel
  • Coated PCB, Fuse
  • Latest release std. SW.
  • Frame: E1H
  • EtherNet/IP MCA 121, MCB-114 VLT Sensor Input
  • No C1 option, MCB-107 24V DC backup
Model code:
FC-102N450T7E5MH2BGC7XQSXXXXANB4CXXXXD0
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® HVAC Drive FC-
Series102
Power RatingN450(N450) 450 KW / 600 HP
PhaseTThree phase
Mains Voltage7525 - 690 VAC *
EnclosureE5MIP54/Type 12+main shield
RFI FilterH2RFI Filter
Brake - Safe StopBBrake chopper
LCPGGraphical Loc. Cont. Panel
Coating PCBCCoated PCB
Mains Option7Fuse
Adaptation AXStandard Cable Entries
Adaptation BQHeat-sink access
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionANEtherNet/IP MCA 121
B OptionB4MCB-114 VLT Sensor Input
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionD0MCB-107 24V DC backup
Frame SizeE1H
Power 110% (NO) [KW]450
Height [mm]2000,0
Width w/ no C options [mm]600,0
Depth [mm]510,0
Depth with Option A/B [mm]510,0
kVA538
Power Loss NO [W]6062
Power Loss NO [W]5939
Continuous Current (NO) [A]470
Intermittent Current (NO) [A]517
Continuous Current (NO) [A]450
Intermittent Current (NO) [A]495
Power Rating at 525-550V355kW
Power Rating at 575V450HP
Power Rating at 690V450kW

Technical data

Motor power450 kW / 600 HP
Mains voltage525 - 690 VAC *
PhaseThree-phase
Protection ratingIP54/Type 12+main shield
Frame sizeE1H
RFI filterClass A2 (EMC C3)
Brake chopperYes
Control panelGraphical LCP
PCB coatingCoated PCB
Mains optionIntegrated Fuse
FieldbusEtherNet/IP MCA 121
Product typeFrequency converter
Continuous output current470 A
Continuous current (high line)450 A
Intermittent output current517 A
Apparent power538 kVA
Power loss6062 W
Power, normal overload450 kW
Height2000 mm
Width600 mm
Depth510 mm
Depth with A/B options510 mm
Net weight295 kg
Gross weight295.3 kg
EAN5710108397487
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 135X3447 are available on request. Ask for documents →

Other 450 kW / 600 HP variants in VLT HVAC Drive FC 102

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery

We only use your details to answer this request. See our privacy policy.