Danfoss VLT AutomationDrive FC 302 FC-302N200T7E5MH2BGC3XXSXXXXALB2CXXXXD0
136G0733

Danfoss 136G0733 - VLT AutomationDrive FC 302 (200 kW / 300 HP, IP54, 525-690V)

  • Frequency converter
  • VLT® AutomationDrive FC-302
  • (N200) 200 KW / 300 HP, Specific Ratings: 160kW@525-550V, 250HP@575V, 200kW@690V
  • Three phase, 525 - 690 VAC *,IP54/Type 12+main shield
  • RFI Filter
  • Brake chopper
  • Graphical Loc. Cont. Panel
  • Coated PCB, Mains Disconnect + Fuse
  • Latest release std. SW.
  • Frame: D7H
  • PROFINET MCA 120, MCB-112 PTC Therm. Card
  • No C1 option, MCB-107 24V DC backup
  • ATEX: II (2) G [Ex eb Gb] [Ex db Gb] / II (2) D [Ex tb Db]
Model code:
FC-302N200T7E5MH2BGC3XXSXXXXALB2CXXXXD0
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® AutomationDrive FC-
Series302
Power RatingN200(N200) 200 KW / 300 HP
PhaseTThree phase
Mains Voltage7525 - 690 VAC *
EnclosureE5MIP54/Type 12+main shield
RFI FilterH2RFI Filter
Brake - Safe StopBBrake chopper
LCPGGraphical Loc. Cont. Panel
Coating PCBCCoated PCB
Mains Option3Mains Disconnect + Fuse
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionALPROFINET MCA 120
B OptionB2MCB-112 PTC Therm. Card
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionD0MCB-107 24V DC backup
Frame SizeD7H
Power 150% (HO) [KW]200
Power 110% (NO) [KW]250
Height [mm]1978,0
Width w/ no C options [mm]420,0
Depth [mm]386,0
Depth with Option A/B [mm]386,0
kVA289
Power Loss NO [W]3723
Power Loss NO [W]3851
Power Loss HO [W]3012
Power Loss HO [W]3123
Continuous Current (NO) [A]303
Intermittent Current (NO) [A]333
Continuous Current (NO) [A]290
Intermittent Current (NO) [A]319
Continuous Current (HO) [A]253
Intermittent Current (HO) [A]380
Continuous Current (HO) [A]242
Intermittent Current (HO) [A]363
ATEX Marking 1ATEX: II (2) G [Ex eb Gb] [Ex
ATEX Marking 2db Gb] / II (2) D [Ex tb Db]
Power Rating at 525-550V160kW
Power Rating at 575V250HP
Power Rating at 690V200kW

Technical data

Motor power200 kW / 300 HP
Mains voltage525 - 690 VAC *
PhaseThree-phase
Protection ratingIP54/Type 12+main shield
Frame sizeD7H
RFI filterClass A2 (EMC C3)
Brake chopperYes
Safe Torque OffYes
Control panelGraphical LCP
PCB coatingCoated PCB
Mains optionMains Disconnect + Fuse
FieldbusPROFINET MCA 120
Product typeFrequency converter
Continuous output current303 A
Continuous current (high line)290 A
Intermittent output current333 A
Continuous current (high overload)253 A
Apparent power289 kVA
Power loss3723 W
Power, normal overload250 kW
Power, high overload200 kW
Height1978 mm
Width420 mm
Depth386 mm
Depth with A/B options386 mm
Net weight200 kg
Gross weight200.3 kg
EAN5710108571733
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 136G0733 are available on request. Ask for documents →

Other 200 kW / 300 HP variants in VLT AutomationDrive FC 302

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery

We only use your details to answer this request. See our privacy policy.