Danfoss VLT HVAC Drive FC 102 FC-102N500T4E21H2UGC3XXSXXXXAXB2CXXXXDX
136G4151

Danfoss 136G4151 - VLT HVAC Drive FC 102 (500 kW / 650 HP, IP21, 380-480V)

  • Frequency Converter
  • VLT® HVAC Drive FC-102
  • (N500) 500 KW / 650 HP,
  • Three phase, 380 - 480 VAC,IP21 / Type 1
  • RFI Filter
  • Brake chopper + Safe stop
  • Graphical Loc. Cont. Panel
  • Coated PCB, Mains Disconnect + Fuse
  • Latest release std. SW.
  • Frame: E2H
  • No A Option, MCB-112 PTC Therm. Card
  • No C1 option, No D option
  • ATEX: II (2) G [Ex eb Gb] [Ex db Gb] / II (2) D [Ex tb Db]
Model code:
FC-102N500T4E21H2UGC3XXSXXXXAXB2CXXXXDX
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® HVAC Drive FC-
Series102
Power RatingN500(N500) 500 KW / 650 HP
PhaseTThree phase
Mains Voltage4380 - 480 VAC
EnclosureE21IP21 / Type 1
RFI FilterH2RFI Filter
Brake - Safe StopUBrake chopper + Safe stop
LCPGGraphical Loc. Cont. Panel
Coating PCBCCoated PCB
Mains Option3Mains Disconnect + Fuse
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionAXNo A Option
B OptionB2MCB-112 PTC Therm. Card
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionDXNo D option
Frame SizeE2H
Power 110% (NO) [KW]500
Height [mm]2000,0
Width w/ no C options [mm]700,0
Depth [mm]510,0
Depth with Option A/B [mm]510,0
kVA610
Power Loss NO [W]9473
Power Loss NO [W]7809
Continuous Current (NO) [A]880
Intermittent Current (NO) [A]968
Continuous Current (NO) [A]780
Intermittent Current (NO) [A]858
ATEX Marking 1ATEX: II (2) G [Ex eb Gb] [Ex
ATEX Marking 2db Gb] / II (2) D [Ex tb Db]

Technical data

Motor power500 kW / 650 HP
Mains voltage380 - 480 VAC
PhaseThree-phase
Protection ratingIP21 / Type 1
Frame sizeE2H
RFI filterClass A2 (EMC C3)
Brake chopperYes
Safe Torque OffYes
Control panelGraphical LCP
PCB coatingCoated PCB
Mains optionMains Disconnect + Fuse
FieldbusNone
Product typeFrequency converter
Continuous output current880 A
Continuous current (high line)780 A
Intermittent output current968 A
Apparent power610 kVA
Power loss9473 W
Power, normal overload500 kW
Height2000 mm
Width700 mm
Depth510 mm
Depth with A/B options510 mm
Net weight318 kg
Gross weight318.3 kg
EAN5710108605896
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 136G4151 are available on request. Ask for documents →

Other 500 kW / 650 HP variants in VLT HVAC Drive FC 102

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery

We only use your details to answer this request. See our privacy policy.