Danfoss VLT Refrigeration Drive FC 103 FC-103N90KT7E54H2XGCXXXSXXXXAXBXCXXXXDX
136N4291

Danfoss 136N4291 - VLT Refrigeration Drive FC 103 (90 kW / 125 HP, IP54, 525-690V)

  • Frequency converter
  • VLT® Refrigeration Drive FC-103
  • (N90K) 90 KW / 125 HP, Specific Ratings: 75kW@525-550V, 100HP@575V, 90kW@690V
  • Three phase, 525 - 690 VAC *,(E54) IP54 / Type 12
  • RFI filter Class A2
  • No brake chopper
  • Graphical Loc. Cont. Panel
  • Coated PCB, No Mains Option
  • Latest release std. SW.
  • No A Option, No B Option
  • No C1 option, No D option
  • Frame: D1H
Model code:
FC-103N90KT7E54H2XGCXXXSXXXXAXBXCXXXXDX
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® Refrigeration Drive
Series103
Power RatingN90K(N90K) 90 KW / 125 HP
PhaseTThree phase
Mains Voltage7525 - 690 VAC *
EnclosureE54(E54) IP54 / Type 12
RFI FilterH2RFI filter Class A2
Brake - Safe StopXNo brake chopper
LCPGGraphical Loc. Cont. Panel
Coating PCBCCoated PCB
Mains OptionXNo Mains Option
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionAXNo A Option
B OptionBXNo B Option
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionDXNo D option
Frame SizeD1H
Power 110% (NO) [KW]90
Height [mm]901,0
Width w/ no C options [mm]325,0
Depth [mm]378,0
Depth with Option A/B [mm]378,0
kVA129
Power Loss NO [W]1426
Power Loss NO [W]1476
Continuous Current (NO) [A]113
Intermittent Current (NO) [A]124
Continuous Current (NO) [A]108
Intermittent Current (NO) [A]119
Power Rating at 525-550V75kW
Power Rating at 575V100HP
Power Rating at 690V90kW

Technical data

Motor power90 kW / 125 HP
Mains voltage525 - 690 VAC *
PhaseThree-phase
Protection ratingIP54 / Type 12
Frame sizeD1H
RFI filterClass A2 (EMC C3)
Brake chopperNo
Control panelGraphical LCP
PCB coatingCoated PCB
Mains optionNone
FieldbusNone
Product typeFrequency converter
Continuous output current113 A
Continuous current (high line)108 A
Intermittent output current124 A
Apparent power129 kVA
Power loss1426 W
Power, normal overload90 kW
Height901 mm
Width325 mm
Depth378 mm
Depth with A/B options378 mm
Net weight62 kg
Gross weight62.3 kg
EAN5710108921088
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 136N4291 are available on request. Ask for documents →

Other 90 kW / 125 HP variants in VLT Refrigeration Drive FC 103

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty

We only use your details to answer this request. See our privacy policy.