Danfoss VLT AutomationDrive FC 302 FC-302N315T7E5MH2XGRJXXSXXXXA0B7CXXXXD0
136N7404

Danfoss 136N7404 - VLT AutomationDrive FC 302 (315 kW / 450 HP, IP54, 525-690V)

  • Frequency converter
  • VLT® AutomationDrive FC-302
  • (N315) 315 KW / 450 HP, Specific Ratings: 250kW@525-550V, 350HP@575V, 315kW@690V
  • Three phase, 525 - 690 VAC *,IP54/Type 12+main shield
  • RFI Filter
  • No brake chopper
  • Graphical Loc. Cont. Panel
  • Coated PCB 3C3 + Ruggedised, Circuit Breaker + Fuse
  • Latest release std. SW.
  • Frame: D8H
  • PROFIBUS DP MCA 101, MCB-151 Safe Option HTL
  • No C1 option, MCB-107 24V DC backup
Model code:
FC-302N315T7E5MH2XGRJXXSXXXXA0B7CXXXXD0
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® AutomationDrive FC-
Series302
Power RatingN315(N315) 315 KW / 450 HP
PhaseTThree phase
Mains Voltage7525 - 690 VAC *
EnclosureE5MIP54/Type 12+main shield
RFI FilterH2RFI Filter
Brake - Safe StopXNo brake chopper
LCPGGraphical Loc. Cont. Panel
Coating PCBRCoated PCB 3C3 + Ruggedised
Mains OptionJCircuit Breaker + Fuse
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionA0PROFIBUS DP MCA 101
B OptionB7MCB-151 Safe Option HTL
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionD0MCB-107 24V DC backup
Frame SizeD8H
Power 150% (HO) [KW]315
Power 110% (NO) [KW]400
Height [mm]2284,0
Width w/ no C options [mm]420,0
Depth [mm]406,0
Depth with Option A/B [mm]406,0
kVA411
Power Loss NO [W]5028
Power Loss NO [W]5155
Power Loss HO [W]4146
Power Loss HO [W]4258
Continuous Current (NO) [A]418
Intermittent Current (NO) [A]460
Continuous Current (NO) [A]400
Intermittent Current (NO) [A]440
Continuous Current (HO) [A]360
Intermittent Current (HO) [A]540
Continuous Current (HO) [A]344
Intermittent Current (HO) [A]516
Power Rating at 525-550V250kW
Power Rating at 575V350HP
Power Rating at 690V315kW

Technical data

Motor power315 kW / 450 HP
Mains voltage525 - 690 VAC *
PhaseThree-phase
Protection ratingIP54/Type 12+main shield
Frame sizeD8H
RFI filterClass A2 (EMC C3)
Brake chopperNo
Safe Torque OffYes
Control panelGraphical LCP
PCB coatingCoated PCB 3C3 + Ruggedised
Mains optionCircuit Breaker + Fuse
FieldbusPROFIBUS DP MCA 101
Product typeFrequency converter
Continuous output current418 A
Continuous current (high line)400 A
Intermittent output current460 A
Continuous current (high overload)360 A
Apparent power411 kVA
Power loss5028 W
Power, normal overload400 kW
Power, high overload315 kW
Height2284 mm
Width420 mm
Depth406 mm
Depth with A/B options406 mm
Net weight206 kg
Gross weight256 kg
EAN5710108952907
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 136N7404 are available on request. Ask for documents →

Other 315 kW / 450 HP variants in VLT AutomationDrive FC 302

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty

We only use your details to answer this request. See our privacy policy.