136U6901
Danfoss 136U6901 - VLT HVAC Drive FC 102 (355 kW / 500 HP, IP21, 380-480V)
- Frequency Converter
- VLT® HVAC Drive FC-102
- (N355) 355 KW / 500 HP,
- Three phase, 380 - 480 VAC,IP21 / Type 1
- RFI Filter
- Safe Stop
- Graphical LCP + USB
- Coated PCB, Mains Disconnect + Fuse
- Latest release std. SW.
- Frame: E1H
- PROFIBUS DP MCA 101, No B Option
- No C1 option, MCB-107 24V DC backup
Model code:
FC-102N355T4E21H2TLC3XQSXXXXA0BXCXXXXD0
FC-102N355T4E21H2TLC3XQSXXXXA0BXCXXXXD0
Similar products
- Genuine Danfoss products
- Danfoss manufacturer warranty
- Reply within one business day
Product details
| Product Group | FC- | VLT® HVAC Drive FC- |
| Series | 102 | |
| Power Rating | N355 | (N355) 355 KW / 500 HP |
| Phase | T | Three phase |
| Mains Voltage | 4 | 380 - 480 VAC |
| Enclosure | E21 | IP21 / Type 1 |
| RFI Filter | H2 | RFI Filter |
| Brake - Safe Stop | T | Safe Stop |
| LCP | L | Graphical LCP + USB |
| Coating PCB | C | Coated PCB |
| Mains Option | 3 | Mains Disconnect + Fuse |
| Adaptation A | X | Standard Cable Entries |
| Adaptation B | Q | Heat-sink access |
| Software Release | SXXX | Latest release std. SW. |
| Software Language Pack | X | Standard Language Pack |
| A Option | A0 | PROFIBUS DP MCA 101 |
| B Option | BX | No B Option |
| C0 Option MCO | CX | No C0 option |
| C1 Option | X | No C1 option |
| C Option Software | XX | No software option |
| D Option | D0 | MCB-107 24V DC backup |
| Frame Size | E1H | |
| Power 110% (NO) [KW] | 355 | |
| Height [mm] | 2000,0 | |
| Width w/ no C options [mm] | 600,0 | |
| Depth [mm] | 510,0 | |
| Depth with Option A/B [mm] | 510,0 | |
| kVA | 456 | |
| Power Loss NO [W] | 6928 | |
| Power Loss NO [W] | 5910 | |
| Continuous Current (NO) [A] | 658 | |
| Intermittent Current (NO) [A] | 724 | |
| Continuous Current (NO) [A] | 590 | |
| Intermittent Current (NO) [A] | 649 |
Technical data
| Motor power | 355 kW / 500 HP | |
| Mains voltage | 380 - 480 VAC | |
| Phase | Three-phase | |
| Protection rating | IP21 / Type 1 | |
| Frame size | E1H | |
| RFI filter | Class A2 (EMC C3) | |
| Brake chopper | No | |
| Safe Torque Off | Yes | |
| Control panel | Graphical LCP + USB | |
| PCB coating | Coated PCB | |
| Mains option | Mains Disconnect + Fuse | |
| Fieldbus | PROFIBUS DP MCA 101 | |
| Product type | Frequency converter | |
| Continuous output current | 658 A | |
| Continuous current (high line) | 590 A | |
| Intermittent output current | 724 A | |
| Apparent power | 456 kVA | |
| Power loss | 6928 W | |
| Power, normal overload | 355 kW | |
| Height | 2000 mm | |
| Width | 600 mm | |
| Depth | 510 mm | |
| Depth with A/B options | 510 mm | |
| Net weight | 295 kg | |
| Gross weight | 295.3 kg | |
| EAN | 5714853050031 | |
| ECCN (EU) | Y901 | |
| ECCN (US) | 3A999.a | |
Documents
Operating guides, design guides, certificates and CAD drawings for 136U6901 are available on request. Ask for documents →
Other 355 kW / 500 HP variants in VLT HVAC Drive FC 102
- 135X4490 IP00 · Class A2 · E3H
- 136G1006 IP00 · Class A2 · E3H
- 137N0052 IP00 · Class A2 · E3H
- 136F0731 IP00 · Class A2 · E3H
- 136G2025 IP00 · Class A2 · E3H
- 135U5250 IP00 · Class A2 · E3H
- 135U5244 IP00 · Class A2 · E3H
- 136H2323 IP00 · Class A1 · E3H
- 135X1952 IP00 · Class A1 · E3H
- 167G3986 IP00 · Class A1 · E3H
- 136G2493 IP00 · Class A1 · E3H
- 136G1027 IP00 · Class A1 · E3H
- 135U3436 IP00 · Class A1 · E3H
- 135N3968 IP00 · Class A2 · DB2
- 136U9507 IP20 · Class A2 · E3H
- 136U9503 IP20 · Class A2 · E3H
- 136U9500 IP20 · Class A2 · E3H
- 136U9421 IP20 · Class A2 · E3H
- 137N2007 IP20 · Class A2 · E3H
- 135X3687 IP20 · Class A2 · E3H
- 137G4377 IP20 · Class A1 · E3H
- 137H5879 IP20 · Class A1 · E3H
- 137G6913 IP20 · Class A2 · E3H