Danfoss VLT AutomationDrive FC 302 FC-302N200T5E5MH4BGC3XXS067XA8B2CXXXXDX
136U9858

Danfoss 136U9858 - VLT AutomationDrive FC 302 (200 kW / 300 HP, IP54, 380-500V)

  • Frequency converter
  • VLT® AutomationDrive FC-302
  • (N200) 200 KW / 300 HP,
  • Three phase, 380 - 500 VAC,IP54/Type 12+main shield
  • RFI class A1 (C2)
  • Brake chopper
  • Graphical Loc. Cont. Panel
  • Coated PCB, Mains Disconnect + Fuse
  • (S067)Integrated MotionControl
  • Frame: D7H
  • EtherCAT MCA 124, MCB-112 PTC Therm. Card
  • No C1 option, No D option
  • ATEX: II (2) G [Ex eb Gb] [Ex db Gb] / II (2) D [Ex tb Db]
Model code:
FC-302N200T5E5MH4BGC3XXS067XA8B2CXXXXDX
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® AutomationDrive FC-
Series302
Power RatingN200(N200) 200 KW / 300 HP
PhaseTThree phase
Mains Voltage5380 - 500 VAC
EnclosureE5MIP54/Type 12+main shield
RFI FilterH4RFI class A1 (C2)
Brake - Safe StopBBrake chopper
LCPGGraphical Loc. Cont. Panel
Coating PCBCCoated PCB
Mains Option3Mains Disconnect + Fuse
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseS067(S067)Integrated MotionControl
Software Language PackXStandard Language Pack
A OptionA8EtherCAT MCA 124
B OptionB2MCB-112 PTC Therm. Card
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionDXNo D option
Frame SizeD7H
Power 150% (HO) [KW]200
Power 110% (NO) [KW]250
Height [mm]1978,0
Width w/ no C options [mm]420,0
Depth [mm]386,0
Depth with Option A/B [mm]386,0
kVA274
Power Loss NO [W]5137
Power Loss NO [W]4566
Power Loss HO [W]4039
Power Loss HO [W]3575
Continuous Current (NO) [A]480
Intermittent Current (NO) [A]528
Continuous Current (NO) [A]443
Intermittent Current (NO) [A]487
Continuous Current (HO) [A]395
Intermittent Current (HO) [A]592
Continuous Current (HO) [A]361
Intermittent Current (HO) [A]542
ATEX Marking 1ATEX: II (2) G [Ex eb Gb] [Ex
ATEX Marking 2db Gb] / II (2) D [Ex tb Db]

Technical data

Motor power200 kW / 300 HP
Mains voltage380 - 500 VAC
PhaseThree-phase
Protection ratingIP54/Type 12+main shield
Frame sizeD7H
RFI filterClass A1 (EMC C2)
Brake chopperYes
Safe Torque OffYes
Control panelGraphical LCP
PCB coatingCoated PCB
Mains optionMains Disconnect + Fuse
FieldbusEtherCAT MCA 124
Product typeFrequency converter
Continuous output current480 A
Continuous current (high line)443 A
Intermittent output current528 A
Continuous current (high overload)395 A
Apparent power274 kVA
Power loss5137 W
Power, normal overload250 kW
Power, high overload200 kW
Height1978 mm
Width420 mm
Depth386 mm
Depth with A/B options386 mm
Net weight225 kg
Gross weight225.3 kg
EAN5714853079957
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 136U9858 are available on request. Ask for documents →

Other 200 kW / 300 HP variants in VLT AutomationDrive FC 302

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery

We only use your details to answer this request. See our privacy policy.