Danfoss VACON NXP Common DC Bus NXB00165-A2T08SV-A1A30000C7+QGLM
136X8557

Danfoss 136X8557 - VACON NXP Common DC Bus (2 kW, IP21, 380-500V)

  • Vacon Brake Chopper Unit
  • 380 – 500 Vac (465-800 Vdc), 16 Amp,IP21/NEMA1
  • Alpha-numeric display
  • IEC61800-3 for IT networks
  • No Brake
  • A Slot: 6DI,DO,2AI,1AO,+10Vr,+24V
  • B Slot: 1RO(NO/NC),1RO(NC), therm
  • C Slot: No board
  • D Slot: No board
  • E Slot: DeviceNet, Spare only
  • Manual: English
  • Frame 06
Model code:
NXB00165-A2T08SV-A1A30000C7+QGLM
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupNXBBrake Chopper Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current001616 Amp
Control KeypadAAlpha-numeric display
Enclosure2IP21/NEMA1
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification8BCU Brake chopper unit
Card ModificationsV-DirectConn. w Varnished Boards
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGLMMetric conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA31RO(NO/NC),1RO(NC), therm
Option Slot C00No board
Option Slot D00No board
Option Slot EC7DeviceNet, Spare only
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ABFIFF01Brake Chopper Unit NXB
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFR06Frame 06
Motor Power Low Overload [kW]2X10
Motor Power High Overload [kW]5.5
Dimensions WxHxD [mm]195X557X237
Continuous Current (NO) [A]2X16
Continuous Current (HO) [A]12

Technical data

Motor power2 kW
Mains voltage380 – 500 Vac (465-800 Vdc)
Protection ratingIP21/NEMA1
Frame sizeFR06
RFI filterNone (EMC C4)
Brake chopperNo
Control panelAlphanumeric Keypad
Product typeBrake Chopper Unit
Continuous output current2 A
Continuous current (high overload)12 A
Rated current16 A
Power, high overload5.5 kW
Power, low overload2 kW
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Height557 mm
Width195 mm
Depth237 mm
Net weight18.5 kg
Gross weight19.5 kg
EAN5714853170579
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 136X8557 are available on request. Ask for documents →

Other 2 kW variants in VACON NXP Common DC Bus

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery

We only use your details to answer this request. See our privacy policy.