Danfoss VLT HVAC Drive FC 102 FC-102N160T7E5MH2TGR7XXSXXXXAXB2CXXXXDX
136Z0715

Danfoss 136Z0715 - VLT HVAC Drive FC 102 (160 kW / 250 HP, IP54, 525-690V)

  • Frequency Converter
  • VLT® HVAC Drive FC-102
  • (N160) 160 KW / 250 HP, Specific Ratings: 132kW@525-550V, 200HP@575V, 160kW@690V
  • Three phase, 525 - 690 VAC *,IP54/Type 12+main shield
  • RFI Filter
  • Safe Stop
  • Graphical Loc. Cont. Panel
  • Coated PCB 3C3 + Ruggedised, Fuse
  • Latest release std. SW.
  • Frame: D1H
  • No A Option, MCB-112 PTC Therm. Card
  • No C1 option, No D option
  • ATEX: II (2) G [Ex eb Gb] [Ex db Gb] / II (2) D [Ex tb Db]
Model code:
FC-102N160T7E5MH2TGR7XXSXXXXAXB2CXXXXDX
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® HVAC Drive FC-
Series102
Power RatingN160(N160) 160 KW / 250 HP
PhaseTThree phase
Mains Voltage7525 - 690 VAC *
EnclosureE5MIP54/Type 12+main shield
RFI FilterH2RFI Filter
Brake - Safe StopTSafe Stop
LCPGGraphical Loc. Cont. Panel
Coating PCBRCoated PCB 3C3 + Ruggedised
Mains Option7Fuse
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionAXNo A Option
B OptionB2MCB-112 PTC Therm. Card
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionDXNo D option
Frame SizeD1H
Power 110% (NO) [KW]160
Height [mm]901,0
Width w/ no C options [mm]325,0
Depth [mm]378,0
Depth with Option A/B [mm]378,0
kVA229
Power Loss NO [W]2646
Power Loss NO [W]2738
Continuous Current (NO) [A]201
Intermittent Current (NO) [A]221
Continuous Current (NO) [A]192
Intermittent Current (NO) [A]211
ATEX Marking 1ATEX: II (2) G [Ex eb Gb] [Ex
ATEX Marking 2db Gb] / II (2) D [Ex tb Db]
Power Rating at 525-550V132kW
Power Rating at 575V200HP
Power Rating at 690V160kW

Technical data

Motor power160 kW / 250 HP
Mains voltage525 - 690 VAC *
PhaseThree-phase
Protection ratingIP54/Type 12+main shield
Frame sizeD1H
RFI filterClass A2 (EMC C3)
Brake chopperNo
Safe Torque OffYes
Control panelGraphical LCP
PCB coatingCoated PCB 3C3 + Ruggedised
Mains optionIntegrated Fuse
FieldbusNone
Product typeFrequency converter
Continuous output current201 A
Continuous current (high line)192 A
Intermittent output current221 A
Apparent power229 kVA
Power loss2646 W
Power, normal overload160 kW
Height901 mm
Width325 mm
Depth378 mm
Depth with A/B options378 mm
Net weight166 kg
Gross weight166.3 kg
EAN5714853194704
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 136Z0715 are available on request. Ask for documents →

Other 160 kW / 250 HP variants in VLT HVAC Drive FC 102

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty