136Z1119
Danfoss 136Z1119 - VLT HVAC Drive FC 102 (2.2 kW / 3 HP, IP20, 525-600V)
- Frequency Converter
- VLT® HVAC Drive FC-102
- (P2K2) 2.2 KW / 3.0 HP,
- Three phase, 525 - 600 VAC,(E20) IP20 / Chassis
- No RFI Filter
- No brake chopper
- Graphical Loc. Cont. Panel
- Not coated PCB, No Mains Option
- Latest release std. SW.
- Frame: A3
- MCA 125 BACnet/IP, No B Option
- No C1 option, No D option
Model code:
FC-102P2K2T6E20HXXGXXXXSXXXXAKBXCXXXXDX
FC-102P2K2T6E20HXXGXXXXSXXXXAKBXCXXXXDX
Similar products
- Genuine Danfoss products
- Danfoss manufacturer warranty
- Reply within one business day
Product details
| Product Group | FC- | VLT® HVAC Drive FC- |
| Series | 102 | |
| Power Rating | P2K2 | (P2K2) 2.2 KW / 3.0 HP |
| Phase | T | Three phase |
| Mains Voltage | 6 | 525 - 600 VAC |
| Enclosure | E20 | (E20) IP20 / Chassis |
| RFI Filter | HX | No RFI Filter |
| Brake - Safe Stop | X | No brake chopper |
| LCP | G | Graphical Loc. Cont. Panel |
| Coating PCB | X | Not coated PCB |
| Mains Option | X | No Mains Option |
| Adaptation A | X | Standard Cable Entries |
| Adaptation B | X | No adaptation |
| Software Release | SXXX | Latest release std. SW. |
| Software Language Pack | X | Standard Language Pack |
| A Option | AK | MCA 125 BACnet/IP |
| B Option | BX | No B Option |
| C0 Option MCO | CX | No C0 option |
| C1 Option | X | No C1 option |
| C Option Software | XX | No software option |
| D Option | DX | No D option |
| Frame Size | A3 | |
| Power 110% (NO) [KW] | 2.2 | |
| Height [mm] | 268,0 | |
| Width w/ no C options [mm] | 130,0 | |
| Width w/ two C options [mm] | 190,0 | |
| Depth [mm] | 205,0 | |
| Depth with Option A/B [mm] | 220,0 | |
| kVA | 3.88 | |
| Power Loss NO [W] | 92 | |
| Continuous Current (NO) [A] | 4.1 | |
| Intermittent Current (NO) [A] | 4.51 | |
| Continuous Current (NO) [A] | 3.9 | |
| Intermittent Current (NO) [A] | 4.29 |
Technical data
| Motor power | 2.2 kW / 3 HP | |
| Mains voltage | 525 - 600 VAC | |
| Phase | Three-phase | |
| Protection rating | IP20 / Chassis | |
| Frame size | A3 | |
| RFI filter | None | |
| Brake chopper | No | |
| Control panel | Graphical LCP | |
| PCB coating | Uncoated | |
| Mains option | None | |
| Fieldbus | MCA 125 BACnet/IP | |
| Product type | Frequency converter | |
| Continuous output current | 4.1 A | |
| Continuous current (high line) | 3.9 A | |
| Intermittent output current | 4.51 A | |
| Apparent power | 3.88 kVA | |
| Power loss | 92 W | |
| Power, normal overload | 2.2 kW | |
| Height | 268 mm | |
| Width | 130 mm | |
| Width with C options | 190 mm | |
| Depth | 205 mm | |
| Depth with A/B options | 220 mm | |
| Net weight | 6.19 kg | |
| Gross weight | 7.196 kg | |
| Packed volume | 27.2 L | |
| EAN | 5714853199600 | |
| ECCN (EU) | Y901 | |
| ECCN (US) | 3A999.a | |
Documents
Operating guides, design guides, certificates and CAD drawings for 136Z1119 are available on request. Ask for documents →
Other 2.2 kW / 3 HP variants in VLT HVAC Drive FC 102
- 131Z2784 IP20 · None · A3
- 167H2453 IP20 · None · A3
- 131Z2252 IP20 · None · A3
- 131U9420 IP20 · None · A3
- 136N8215 IP20 · None · A3
- 131N3881 IP20 · None · A3
- 135N8495 IP20 · None · A3
- 131U9241 IP20 · None · A3
- 131Z3645 IP20 · None · A3
- 134X0059 IP20 · None · A3
- 131L7938 IP20 · None · A3
- 134G9133 IP20 · None · A3
- 131X7038 IP20 · None · A3
- 131G9195 IP20 · None · A3
- 131G7688 IP20 · None · A3
- 137G1191 IP20 · None · A3
- 137U4415 IP20 · None · A3
- 136N5118 IP20 · None · A3
- 134L7394 IP20 · None · A3
- 132L0789 IP20 · None · A3
- 131L4002 IP20 · None · A3
- 131L5181 IP20 · None · A3
- 131L8972 IP20 · None · A3
- 131N4611 IP20 · None · A3