Danfoss VLT HVAC Drive FC 102 FC-102P500T4E54N2TGC7XKSXXXXANB2CXXXXD0
137G2953

Danfoss 137G2953 - VLT HVAC Drive FC 102 (500 kW / 650 HP, IP54, 380-480V)

  • Frequency Converter
  • VLT® HVAC Drive FC-102
  • (P500) 500 KW / 650 HP, Three phase
  • 380 - 480 VAC, (E54) IP54 / Type 12
  • LHD - AAF006 filter + A2 RFI
  • Safe Stop
  • Graphical Loc. Cont. Panel
  • Coated PCB, Fuse
  • Latest release std. SW.
  • Frame: F18
  • No C1 option, MCB-107 24V DC backup
  • EtherNet/IP MCA 121, MCB-112 PTC Therm. Card
  • ATEX: II (2) G [Ex eb Gb] [Exdb Gb] / II (2) D [Ex tb Db]
Model code:
FC-102P500T4E54N2TGC7XKSXXXXANB2CXXXXD0
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® HVAC Drive FC-
Series102
Power RatingP500(P500) 500 KW / 650 HP
PhaseTThree phase
Mains Voltage4380 - 480 VAC
EnclosureE54(E54) IP54 / Type 12
RFI FilterN2LHD - AAF006 filter + A2 RFI
Brake - Safe StopTSafe Stop
LCPGGraphical Loc. Cont. Panel
Coating PCBCCoated PCB
Mains Option7Fuse
Adaptation AXStandard Cable Entries
Adaptation BKF Frame Common Motor Term
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionANEtherNet/IP MCA 121
B OptionB2MCB-112 PTC Therm. Card
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionD0MCB-107 24V DC backup
Frame SizeF18
Power 110% (NO) [KW]500
Height [mm]2277,0
Width w/ no C options [mm]2802,0
Depth [mm]607,0
Depth with Option A/B [mm]607,0
kVA610
Power Loss NO [W]21909
Power Loss NO [W]19896
Continuous Current (NO) [A]880
Intermittent Current (NO) [A]968
Continuous Current (NO) [A]780
Intermittent Current (NO) [A]858
ATEX Marking 1ATEX: II (2) G [Ex eb Gb] [Ex
ATEX Marking 2db Gb] / II (2) D [Ex tb Db]

Technical data

Motor power500 kW / 650 HP
Mains voltage380 - 480 VAC
PhaseThree-phase
Protection ratingIP54 / Type 12
Frame sizeF18
RFI filterClass A2 (EMC C3)
Brake chopperNo
Safe Torque OffYes
Control panelGraphical LCP
PCB coatingCoated PCB
Mains optionIntegrated Fuse
FieldbusEtherNet/IP MCA 121
Product typeFrequency converter
Continuous output current880 A
Continuous current (high line)780 A
Intermittent output current968 A
Apparent power610 kVA
Power loss21909 W
Power, normal overload500 kW
Height2277 mm
Width2802 mm
Depth607 mm
Depth with A/B options607 mm
Net weight1899 kg
Gross weight1899.3 kg
Packed volume0 L
EAN5715253289175
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 137G2953 are available on request. Ask for documents →

Other 500 kW / 650 HP variants in VLT HVAC Drive FC 102

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery

We only use your details to answer this request. See our privacy policy.