Danfoss VLT AutomationDrive FC 302 FC-302N500T7E2MH2XLC7XXLX1XXA0B2CXXXXD0
137G8526

Danfoss 137G8526 - VLT AutomationDrive FC 302 (500 kW / 650 HP, IP21, 525-690V)

  • Frequency converter
  • VLT® AutomationDrive FC-302
  • (N500) 500 KW / 650 HP, Specific Ratings: 400kW@525-550V, 500HP@575V, 500kW@690V
  • Three phase, 525 - 690 VAC *,IP21/Type 1+mains shield
  • RFI Filter
  • No brake chopper
  • Graphical LCP + USB
  • Coated PCB, Fuse
  • Condition Based Monitoring CBM
  • Frame: E1H
  • PROFIBUS DP MCA 101, MCB-112 PTC Therm. Card
  • No C1 option, MCB-107 24V DC backup
  • ATEX: II (2) G [Ex eb Gb] [Ex db Gb] / II (2) D [Ex tb Db]
Model code:
FC-302N500T7E2MH2XLC7XXLX1XXA0B2CXXXXD0
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® AutomationDrive FC-
Series302
Power RatingN500(N500) 500 KW / 650 HP
PhaseTThree phase
Mains Voltage7525 - 690 VAC *
EnclosureE2MIP21/Type 1+mains shield
RFI FilterH2RFI Filter
Brake - Safe StopXNo brake chopper
LCPLGraphical LCP + USB
Coating PCBCCoated PCB
Mains Option7Fuse
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseLX1XCondition Based Monitoring CBM
Software Language PackXStandard Language Pack
A OptionA0PROFIBUS DP MCA 101
B OptionB2MCB-112 PTC Therm. Card
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionD0MCB-107 24V DC backup
Frame SizeE1H
Power 150% (HO) [KW]500
Power 110% (NO) [KW]560
Height [mm]2000,0
Width w/ no C options [mm]600,0
Depth [mm]510,0
Depth with Option A/B [mm]510,0
kVA598
Power Loss NO [W]8076
Power Loss NO [W]7852
Power Loss HO [W]6833
Power Loss HO [W]6678
Continuous Current (NO) [A]596
Intermittent Current (NO) [A]656
Continuous Current (NO) [A]570
Intermittent Current (NO) [A]627
Continuous Current (HO) [A]523
Intermittent Current (HO) [A]784
Continuous Current (HO) [A]500
Intermittent Current (HO) [A]750
ATEX Marking 1ATEX: II (2) G [Ex eb Gb] [Ex
ATEX Marking 2db Gb] / II (2) D [Ex tb Db]
Power Rating at 525-550V400kW
Power Rating at 575V500HP
Power Rating at 690V500kW

Technical data

Motor power500 kW / 650 HP
Mains voltage525 - 690 VAC *
PhaseThree-phase
Protection ratingIP21/Type 1+mains shield
Frame sizeE1H
RFI filterClass A2 (EMC C3)
Brake chopperNo
Safe Torque OffYes
Control panelGraphical LCP + USB
PCB coatingCoated PCB
Mains optionIntegrated Fuse
FieldbusPROFIBUS DP MCA 101
Product typeFrequency converter
Continuous output current596 A
Continuous current (high line)570 A
Intermittent output current656 A
Continuous current (high overload)523 A
Apparent power598 kVA
Power loss8076 W
Power, normal overload560 kW
Power, high overload500 kW
Height2000 mm
Width600 mm
Depth510 mm
Depth with A/B options510 mm
Net weight295 kg
Gross weight295.3 kg
EAN5715253348759
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 137G8526 are available on request. Ask for documents →

Other 500 kW / 650 HP variants in VLT AutomationDrive FC 302

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery

We only use your details to answer this request. See our privacy policy.