Danfoss VLT Refrigeration Drive FC 103 FC-103P37KT4E66H2XGCXXXLX1XXAXB0CXXXXDX
137L0146

Danfoss 137L0146 - VLT Refrigeration Drive FC 103 (37 kW / 50 HP, IP66, 380-480V)

  • Frequency converter
  • VLT® Refrigeration Drive FC-103
  • 37 KW / 50 HP,
  • Three phase, 380 - 480 VAC, (E66) IP66 / NEMA 4X
  • RFI filter Class A2
  • No brake chopper
  • Graphical Loc. Cont. Panel
  • Coated PCB, No Mains Option
  • No adaptation
  • Condition Based Monitoring CBM
  • No A Option, MCB-109 I/O, RTC Back-up
  • No C1 option, No D option
  • Frame: C1
Model code:
FC-103P37KT4E66H2XGCXXXLX1XXAXB0CXXXXDX
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® Refrigeration Drive
Series103
Power RatingP37K37 KW / 50 HP
PhaseTThree phase
Mains Voltage4380 - 480 VAC
EnclosureE66(E66) IP66 / NEMA 4X
RFI FilterH2RFI filter Class A2
Brake - Safe StopXNo brake chopper
LCPGGraphical Loc. Cont. Panel
Coating PCBCCoated PCB
Mains OptionXNo Mains Option
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseLX1XCondition Based Monitoring CBM
Software Language PackXStandard Language Pack
A OptionAXNo A Option
B OptionB0MCB-109 I/O, RTC Back-up
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionDXNo D option
Frame SizeC1
Power 110% (NO) [KW]37
kVA50.6
Power Loss NO [W]739
Continuous Current (NO) [A]73
Intermittent Current (NO) [A]80.3
Continuous Current (NO) [A]65
Intermittent Current (NO) [A]71.5
Height [mm]685,0
Width w/ no C options [mm]308,0
Depth [mm]311,0
Depth with Option A/B [mm]311,0

Technical data

Motor power37 kW / 50 HP
Mains voltage380 - 480 VAC
PhaseThree-phase
Protection ratingIP66 / NEMA 4X
Frame sizeC1
RFI filterClass A2 (EMC C3)
Brake chopperNo
Control panelGraphical LCP
PCB coatingCoated PCB
Mains optionNone
FieldbusNone
Product typeFrequency converter
Continuous output current73 A
Continuous current (high line)65 A
Intermittent output current80.3 A
Apparent power50.6 kVA
Power loss739 W
Power, normal overload37 kW
Height685 mm
Width308 mm
Depth311 mm
Depth with A/B options311 mm
Net weight38.37 kg
Gross weight41.37 kg
Packed volume158.1 L
EAN5715253471563
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 137L0146 are available on request. Ask for documents →

Other 37 kW / 50 HP variants in VLT Refrigeration Drive FC 103

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty

We only use your details to answer this request. See our privacy policy.