Danfoss VACON 100 FLOW Enclosed Drive VACON0100-3L-0651-5-ED-FLOW+SBF4+SCB4+SRBT+IP54+FBIE+CAPU+CAPD+CIFD+CDLP+CACH+CAMH+CHCB+EMAR+GNUL
137L2100

Danfoss 137L2100 - VACON 100 FLOW Enclosed Drive (355 kW / 500 HP, IP54, 380-500V)

  • Frequency converter
  • VACON 100 FLOW
  • 380-500 Vac 651 AmpIP54/NEMA12
  • Graphical Keypad MK01
  • C3 Commercial&Industry Environ
  • B Slot: F4,2 Relay board with therm
  • C Slot: B4,AI,2AO(mA,isol),+24V/EXT
  • D Slot: No board
  • E Slot: No board
  • Fieldbus: IndEth (ProfinetIO,EthernetIP)
  • Manual: English
  • MR11
Model code:
VACON0100-3L-0651-5-ED-FLOW+SBF4+SCB4+SRBT+IP54+FBIE+CAPU+CAPD+CIFD+CDLP+CACH+CAMH+CHCB+EMAR+GNUL
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Segment-FLOWVACON 100 FLOW
Mains voltage-5380-500 Vac
Current rating-0651651 Amp
Installation options-EDED Enclosed Drive
Enclosure+IP54IP54/NEMA12
Control panel+HMGRGraphical Keypad MK01
EMC emission limit category+EMC3C3 Commercial&Industry Environ
Common mode filter (for DM)+P000No Option
DUT filter (for DM)+P000No Option
Brake chopper+DBNONo dynamic braking device
Real time clock option+SRBTBattery for real time clock
Configurable power rangeNONENone
Power connections+P000No Power options (+P000)
Cable entry+Q000No option
Additional Equipment B+Q000No option for Qxxx_B (+Q000)
Additonal Equipment C+Q000No additonal option for Qxxx_C
Shipping package+GSWPWooden box as shipping pack
Marine construction+EMARMarine construction
B-Slot Option Board+SBF4F4,2 Relay board with therm
C- Slot Option Board+SCB4B4,AI,2AO(mA,isol),+24V/EXT
D-Slot Option Board+SD00No board
E-Slot Option Board+SE00No board
Internal FB selection+FBIEIndEth (ProfinetIO,EthernetIP)
Documentation level+DPAPPaper Manuals
Document language preference+DLUKEnglish
Firmware Language Pack+FL01UK, DE, FI, SE, IT, FR lang
Application+A0000No Application
Parameter Set+L0000No application parameter set
Motor parameter default freq+LS5050 Hz def motor freq settings
Unit for measure for display+LSSIMetric Units of Measure
Labeling options+LPC1no additional labels
UL approval+GNULNo Ul Approval (+GNUL)
Marine approvalNONENone
RCM Approval+GACTRCM Approval N16307
KC approval+GAKCKC Approval
Ukrainian approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Auxilary power supply+CAPUTerminals for aux power supply
DC power supply for aux device+CAPD24V DC power supply
AC socket for aux devices+C000no option
Input Devices+CIFD(+CIFD) Fuse Switch
Common mode filter (for ED)+P000no option
DU/DT, Sine filter (for ED)+P000no option
Terminal Options+CTIOI/O Terminals
Door Equipments+CDLPSignal lights and reset button
Cabinet heater+CACHCabinet heater
Cabinet light+C000no option
Motor heater control+CAMHMotor heater control
Emergency stop options+C000no option
Insulation fault sensor+C000no option
Cabling from top+C000no option
Back channel cooling+CHCBBack Channel Cooling
Cabinet Plinth+C000no option
Empty extension segmentNONENone
Standardized cabinet solutionNONENone
Engineered cabinet solutionNONENone
Product GroupVACON
Product Series0100Vacon 100 series
Phase-3L3 Phase AC Input
Customized+BM2HVacon 100-FLOW
Main Circuit+M000NONE
Firmware+F0159Vacon0100-Flow Software pack
Max output frequencyNONENone
Terminal Box+T000NONE
Bypass Control Operation ModeNONEnone_
Bypass Input TypeNONEnone_
Bypass power connection typeNONEnone_
CE approval+GACECE Approval (+GACE)
ATEX ApprovalNONENone
County Specific ApprovalNONENone
Warrenty time+WT01Warranty 12/18 months (+WT01)
Frame SizeMR11
Motor Power Low Overload [kW]355
Dimensions WxHxD [mm] net1206 X 2055 X 639
Dimensions WxHxD [mm] Gross1355 X 2440 X 800
Continuous Current (NO) [A]650
Motor Power HP Low Overload500
STAT NO10761
Variant condition (ref. YV00)-5-EDMR11+IP54 -5MR11+IP54 -FLOW-5-0651-ED+IP54 -FLOW-5-EDMR11+IP54 -FLOW-5MR11+IP54 0100+DBNOMR11 0100+DPAP 0100+EMC3 0100+FBIE 0100+HMGR 0100+L0000MR11 0100+P000MR11 0100+Q000MR11 0100+SBF4 0100+SCB4 0100+SD00 0100+SE00 0100+SRBT 0100+WT01 0100-0651-5-ED+CIFD 0100-ED+C000 0100-ED+C000MR11 0100-ED+CACHMR11 0100-ED+CAMH 0100-ED+CAPD 0100-ED+CAPU 0100-ED+CDLP 0100-ED+CHCBMR11 0100-ED+CIFDMR11 0100-ED+CTIO 0100-ED+EMARMR11 0100-ED+GSWPMR11 0100-ED+P000MR11 0100-EDMR11NONE 0100-EDNONE 10761 PILOT VACON VACON0100 VACON0100-5 VACON0100-5MR11 VACON0100-FLOW VACON0100-FLOW-5 VACON0100-FLOW-5-ED VACON0100-FLOW-5MR11 VACON0100-FLOW-ED VACON0100-FLOW-EDMR11 VACON0100-FLOWMR11 VACON0100MR11 VACON0100MR11+IP54
Variant condition (Purch)-5-EDMR11+IP54 -5MR11+IP54 -FLOW-5-0651-ED+IP54 -FLOW-5-EDMR11+IP54 -FLOW-5MR11+IP54 0100+DBNOMR11 0100+DPAP 0100+EMC3 0100+FBIE 0100+HMGR 0100+L0000MR11 0100+P000MR11 0100+Q000MR11 0100+SBF4 0100+SCB4 0100+SD00 0100+SE00 0100+SRBT 0100+WT01 0100-0651-5-ED+CIFD 0100-ED+C000 0100-ED+C000MR11 0100-ED+CACHMR11 0100-ED+CAMH 0100-ED+CAPD 0100-ED+CAPU 0100-ED+CDLP 0100-ED+CHCBMR11 0100-ED+CIFDMR11 0100-ED+CTIO 0100-ED+EMARMR11 0100-ED+GSWPMR11 0100-ED+P000MR11 0100-EDMR11NONE 0100-EDNONE 10761 PILOT VACON VACON0100 VACON0100-5 VACON0100-5MR11 VACON0100-FLOW VACON0100-FLOW-5 VACON0100-FLOW-5-ED VACON0100-FLOW-5MR11 VACON0100-FLOW-ED VACON0100-FLOW-EDMR11 VACON0100-FLOWMR11 VACON0100MR11 VACON0100MR11+IP54
MethodHORIZONTAL

Technical data

Motor power355 kW / 500 HP
Mains voltage380-500 Vac
PhaseThree-phase
Protection ratingIP54/NEMA12
Frame sizeMR11
RFI filterClass A2 (EMC C3)
Brake chopperNo
Control panelGraphical Keypad
Mains optionFuse Switch
FieldbusIndEth (ProfinetIO,EthernetIP)
Product typeEnclosed drive
Continuous output current650 A
Rated current651 A
Power, low overload355 kW
Height2055 mm
Width1206 mm
Depth639 mm
Net weight693.6 kg
Gross weight694.6 kg
EAN5715253491523
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 137L2100 are available on request. Ask for documents →

Other 355 kW / 500 HP variants in VACON 100 FLOW Enclosed Drive

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery

We only use your details to answer this request. See our privacy policy.