137N0412
Danfoss 137N0412 - VLT HVAC Drive FC 102 (400 kW / 550 HP, IP21, 525-690V)
- Frequency Converter
- VLT® HVAC Drive FC-102
- (N400) 400 KW / 550 HP, Specific Ratings: 315kW@525-550V, 400HP@575V, 400kW@690V
- Three phase, 525 - 690 VAC *,IP21/Type 1+mains shield
- RFI Filter
- Safe Stop
- Graphical LCP + USB
- Coated PCB, Mains Disconnect + Fuse
- Condition Based Monitoring CBM
- Frame: D7H
- PROFINET MCA 120, No B Option
- No C1 option, MCB-107 24V DC backup
Model code:
FC-102N400T7E2MH2TLC3XQLX1XXALBXCXXXXD0
FC-102N400T7E2MH2TLC3XQLX1XXALBXCXXXXD0
Similar products
- Genuine Danfoss products
- Danfoss manufacturer warranty
- Reply within one business day
Product details
| Product Group | FC- | VLT® HVAC Drive FC- |
| Series | 102 | |
| Power Rating | N400 | (N400) 400 KW / 550 HP |
| Phase | T | Three phase |
| Mains Voltage | 7 | 525 - 690 VAC * |
| Enclosure | E2M | IP21/Type 1+mains shield |
| RFI Filter | H2 | RFI Filter |
| Brake - Safe Stop | T | Safe Stop |
| LCP | L | Graphical LCP + USB |
| Coating PCB | C | Coated PCB |
| Mains Option | 3 | Mains Disconnect + Fuse |
| Adaptation A | X | Standard Cable Entries |
| Adaptation B | Q | Heat-sink access |
| Software Release | LX1X | Condition Based Monitoring CBM |
| Software Language Pack | X | Standard Language Pack |
| A Option | AL | PROFINET MCA 120 |
| B Option | BX | No B Option |
| C0 Option MCO | CX | No C0 option |
| C1 Option | X | No C1 option |
| C Option Software | XX | No software option |
| D Option | D0 | MCB-107 24V DC backup |
| Frame Size | D7H | |
| Power 110% (NO) [KW] | 400 | |
| Height [mm] | 1978,0 | |
| Width w/ no C options [mm] | 420,0 | |
| Depth [mm] | 386,0 | |
| Depth with Option A/B [mm] | 386,0 | |
| kVA | 478 | |
| Power Loss NO [W] | 5023 | |
| Power Loss NO [W] | 5150 | |
| Continuous Current (NO) [A] | 418 | |
| Intermittent Current (NO) [A] | 460 | |
| Continuous Current (NO) [A] | 400 | |
| Intermittent Current (NO) [A] | 440 | |
| Power Rating at 525-550V | 315kW | |
| Power Rating at 575V | 400HP | |
| Power Rating at 690V | 400kW |
Technical data
| Motor power | 400 kW / 550 HP | |
| Mains voltage | 525 - 690 VAC * | |
| Phase | Three-phase | |
| Protection rating | IP21/Type 1+mains shield | |
| Frame size | D7H | |
| RFI filter | Class A2 (EMC C3) | |
| Brake chopper | No | |
| Safe Torque Off | Yes | |
| Control panel | Graphical LCP + USB | |
| PCB coating | Coated PCB | |
| Mains option | Mains Disconnect + Fuse | |
| Fieldbus | PROFINET MCA 120 | |
| Product type | Frequency converter | |
| Continuous output current | 418 A | |
| Continuous current (high line) | 400 A | |
| Intermittent output current | 460 A | |
| Apparent power | 478 kVA | |
| Power loss | 5023 W | |
| Power, normal overload | 400 kW | |
| Height | 1978 mm | |
| Width | 420 mm | |
| Depth | 386 mm | |
| Depth with A/B options | 386 mm | |
| Net weight | 200 kg | |
| Gross weight | 200.3 kg | |
| EAN | 5715253581293 | |
| ECCN (EU) | Y901 | |
| ECCN (US) | 3A999.a | |
Documents
Operating guides, design guides, certificates and CAD drawings for 137N0412 are available on request. Ask for documents →
Other 400 kW / 550 HP variants in VLT HVAC Drive FC 102
- 136U2559 IP00 · Class A2 · DB2
- 134L2754 IP20 · Class A2 · D4H
- 134U0560 IP20 · Class A2 · D4H
- 134N9530 IP20 · Class A2 · D4H
- 167G3137 IP20 · Class A2 · D4H
- 134N4058 IP20 · Class A2 · D4H
- 134L4700 IP20 · Class A2 · D4H
- 136F9668 IP20 · Class A2 · D4H
- 137G0996 IP20 · Class A2 · D4H
- 134N7968 IP20 · Class A2 · D4H
- 134L5600 IP20 · Class A2 · D4H
- 134N7755 IP20 · Class A2 · D4H
- 134N3186 IP20 · Class A2 · D4H
- 134U6838 IP20 · Class A2 · D4H
- 134H1622 IP20 · Class A2 · D4H
- 134N3888 IP20 · Class A2 · D4H
- 134U8978 IP20 · Class A2 · D4H
- 135N4194 IP20 · Class A2 · D4H
- 134G9290 IP20 · Class A2 · D4H
- 134G5658 IP20 · Class A2 · D4H
- 134H7895 IP20 · Class A2 · D4H
- 134G7874 IP20 · Class A2 · D4H
- 134U9372 IP21 · Class A2 · D8H
- 134H3883 IP21 · Class A2 · D7H