Danfoss VLT AutomationDrive FC 302 FC-302N250T5E5MH4XLC3XXSXXXXA0B2CXXXXD0
137N7881

Danfoss 137N7881 - VLT AutomationDrive FC 302 (250 kW / 350 HP, IP54, 380-500V)

  • Frequency converter
  • VLT® AutomationDrive FC-302
  • (N250) 250 KW / 350 HP,
  • Three phase, 380 - 500 VAC,IP54/Type 12+main shield
  • RFI class A1 (C2)
  • No brake chopper
  • Graphical LCP + USB
  • Coated PCB, Mains Disconnect + Fuse
  • Latest release std. SW.
  • Frame: D7H
  • PROFIBUS DP MCA 101, MCB-112 PTC Therm. Card
  • No C1 option, MCB-107 24V DC backup
  • ATEX: II (2) G [Ex eb Gb] [Ex db Gb] / II (2) D [Ex tb Db]
Model code:
FC-302N250T5E5MH4XLC3XXSXXXXA0B2CXXXXD0
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® AutomationDrive FC-
Series302
Power RatingN250(N250) 250 KW / 350 HP
PhaseTThree phase
Mains Voltage5380 - 500 VAC
EnclosureE5MIP54/Type 12+main shield
RFI FilterH4RFI class A1 (C2)
Brake - Safe StopXNo brake chopper
LCPLGraphical LCP + USB
Coating PCBCCoated PCB
Mains Option3Mains Disconnect + Fuse
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionA0PROFIBUS DP MCA 101
B OptionB2MCB-112 PTC Therm. Card
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionD0MCB-107 24V DC backup
Frame SizeD7H
Power 150% (HO) [KW]250
Power 110% (NO) [KW]315
Height [mm]1978,0
Width w/ no C options [mm]420,0
Depth [mm]386,0
Depth with Option A/B [mm]386,0
kVA333
Power Loss NO [W]6674
Power Loss NO [W]5714
Power Loss HO [W]5004
Power Loss HO [W]4458
Continuous Current (NO) [A]588
Intermittent Current (NO) [A]647
Continuous Current (NO) [A]535
Intermittent Current (NO) [A]588
Continuous Current (HO) [A]480
Intermittent Current (HO) [A]720
Continuous Current (HO) [A]443
Intermittent Current (HO) [A]664
ATEX Marking 1ATEX: II (2) G [Ex eb Gb] [Ex
ATEX Marking 2db Gb] / II (2) D [Ex tb Db]

Technical data

Motor power250 kW / 350 HP
Mains voltage380 - 500 VAC
PhaseThree-phase
Protection ratingIP54/Type 12+main shield
Frame sizeD7H
RFI filterClass A1 (EMC C2)
Brake chopperNo
Safe Torque OffYes
Control panelGraphical LCP + USB
PCB coatingCoated PCB
Mains optionMains Disconnect + Fuse
FieldbusPROFIBUS DP MCA 101
Product typeFrequency converter
Continuous output current588 A
Continuous current (high line)535 A
Intermittent output current647 A
Continuous current (high overload)480 A
Apparent power333 kVA
Power loss6674 W
Power, normal overload315 kW
Power, high overload250 kW
Height1978 mm
Width420 mm
Depth386 mm
Depth with A/B options386 mm
Net weight200 kg
Gross weight200.3 kg
EAN5715253660042
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 137N7881 are available on request. Ask for documents →

Other 250 kW / 350 HP variants in VLT AutomationDrive FC 302

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery