137N8303
Danfoss 137N8303 - VLT HVAC Drive FC 102 (500 kW / 650 HP, IP20, 525-690V)
- Frequency Converter
- VLT® HVAC Drive FC-102
- (N500) 500 KW / 650 HP, Specific Ratings: 400kW@525-550V, 500HP@575V, 500kW@690V
- Three phase, 525 - 690 VAC *,(E20) IP20 / Chassis
- RFI Filter
- Safe Stop
- Graphical Loc. Cont. Panel
- Coated PCB, Fuse
- Condition Based Monitoring CBM
- Frame: E3H
- PROFINET MCA 120, MCB-112 PTC Therm. Card
- No C1 option, MCB-107 24V DC backup
- ATEX: II (2) G [Ex eb Gb] [Ex db Gb] / II (2) D [Ex tb Db]
Model code:
FC-102N500T7E20H2TGC7XQLX1XXALB2CXXXXD0
FC-102N500T7E20H2TGC7XQLX1XXALB2CXXXXD0
Similar products
- Genuine Danfoss products
- Danfoss manufacturer warranty
- Reply within one business day
Product details
| Product Group | FC- | VLT® HVAC Drive FC- |
| Series | 102 | |
| Power Rating | N500 | (N500) 500 KW / 650 HP |
| Phase | T | Three phase |
| Mains Voltage | 7 | 525 - 690 VAC * |
| Enclosure | E20 | (E20) IP20 / Chassis |
| RFI Filter | H2 | RFI Filter |
| Brake - Safe Stop | T | Safe Stop |
| LCP | G | Graphical Loc. Cont. Panel |
| Coating PCB | C | Coated PCB |
| Mains Option | 7 | Fuse |
| Adaptation A | X | Standard Cable Entries |
| Adaptation B | Q | Heat-sink access |
| Software Release | LX1X | Condition Based Monitoring CBM |
| Software Language Pack | X | Standard Language Pack |
| A Option | AL | PROFINET MCA 120 |
| B Option | B2 | MCB-112 PTC Therm. Card |
| C0 Option MCO | CX | No C0 option |
| C1 Option | X | No C1 option |
| C Option Software | XX | No software option |
| D Option | D0 | MCB-107 24V DC backup |
| Frame Size | E3H | |
| Power 110% (NO) [KW] | 500 | |
| Height [mm] | 1578,0 | |
| Width w/ no C options [mm] | 507,0 | |
| Depth [mm] | 482,0 | |
| Depth with Option A/B [mm] | 482,0 | |
| kVA | 598 | |
| Power Loss NO [W] | 6879 | |
| Power Loss NO [W] | 6715 | |
| Continuous Current (NO) [A] | 523 | |
| Intermittent Current (NO) [A] | 575 | |
| Continuous Current (NO) [A] | 500 | |
| Intermittent Current (NO) [A] | 550 | |
| ATEX Marking 1 | ATEX: II (2) G [Ex eb Gb] [Ex | |
| ATEX Marking 2 | db Gb] / II (2) D [Ex tb Db] | |
| Power Rating at 525-550V | 400kW | |
| Power Rating at 575V | 500HP | |
| Power Rating at 690V | 500kW |
Technical data
| Motor power | 500 kW / 650 HP | |
| Mains voltage | 525 - 690 VAC * | |
| Phase | Three-phase | |
| Protection rating | IP20 / Chassis | |
| Frame size | E3H | |
| RFI filter | Class A2 (EMC C3) | |
| Brake chopper | No | |
| Safe Torque Off | Yes | |
| Control panel | Graphical LCP | |
| PCB coating | Coated PCB | |
| Mains option | Integrated Fuse | |
| Fieldbus | PROFINET MCA 120 | |
| Product type | Frequency converter | |
| Continuous output current | 523 A | |
| Continuous current (high line) | 500 A | |
| Intermittent output current | 575 A | |
| Apparent power | 598 kVA | |
| Power loss | 6879 W | |
| Power, normal overload | 500 kW | |
| Height | 1578 mm | |
| Width | 507 mm | |
| Depth | 482 mm | |
| Depth with A/B options | 482 mm | |
| Net weight | 272 kg | |
| Gross weight | 272.3 kg | |
| EAN | 5715253664347 | |
| ECCN (EU) | Y901 | |
| ECCN (US) | 3A999.a | |
Documents
Operating guides, design guides, certificates and CAD drawings for 137N8303 are available on request. Ask for documents →
Other 500 kW / 650 HP variants in VLT HVAC Drive FC 102
- 135U2903 IP20 · Class A2 · E3H
- 136F4767 IP20 · Class A2 · E3H
- 136U8499 IP20 · Class A2 · E3H
- 137X5446 IP20 · Class A2 · E3H
- 135U4002 IP20 · Class A2 · E3H
- 136X4300 IP20 · Class A2 · E3H
- 137U6284 IP20 · Class A2 · E3H
- 137H2321 IP20 · Class A2 · E3H
- 135U3789 IP20 · Class A2 · E3H
- 136G1280 IP20 · Class A2 · E3H
- 137G1454 IP21 · Class A2 · E1H
- 135U3091 IP21 · Class A2 · E1H
- 135U3423 IP21 · Class A2 · E1H
- 132L1890 IP21 · Class A2 · E1H
- 131Z8407 IP21 · Class A2 · F9
- 134H0248 IP21 · Class A2 · F9
- 131X3085 IP21 · Class A2
- 131U9993 IP21 · Class A2
- 134F1758 IP21 · Class A2
- 132X3958 IP54 · Class A2 · E1H
- 167G0550 IP54 · Class A2 · E1H
- 135U4017 IP54 · Class A2 · E1H
- 135U4011 IP54 · Class A2 · E1H