137U7055
Danfoss 137U7055 - VLT HVAC Drive FC 102 (160 kW / 250 HP, IP21, 525-690V)
- Frequency Converter
- VLT® HVAC Drive FC-102
- (N160) 160 KW / 250 HP, Specific Ratings: 132kW@525-550V, 200HP@575V, 160kW@690V
- Three phase, 525 - 690 VAC *,IP21/Type 1+mains shield
- RFI Filter
- Safe Stop
- Graphical Loc. Cont. Panel
- Coated PCB, Mains Disconnect + Fuse
- Latest release std. SW.
- Frame: D5H
- Modbus TCP MCA 122, MCB-114 VLT Sensor Input
- No C1 option, No D option
Model code:
FC-102N160T7E2MH2TGC3XXSXXXXAQB4CXXXXDX
FC-102N160T7E2MH2TGC3XXSXXXXAQB4CXXXXDX
Similar products
- Genuine Danfoss products
- Danfoss manufacturer warranty
- Reply within one business day
Product details
| Product Group | FC- | VLT® HVAC Drive FC- |
| Series | 102 | |
| Power Rating | N160 | (N160) 160 KW / 250 HP |
| Phase | T | Three phase |
| Mains Voltage | 7 | 525 - 690 VAC * |
| Enclosure | E2M | IP21/Type 1+mains shield |
| RFI Filter | H2 | RFI Filter |
| Brake - Safe Stop | T | Safe Stop |
| LCP | G | Graphical Loc. Cont. Panel |
| Coating PCB | C | Coated PCB |
| Mains Option | 3 | Mains Disconnect + Fuse |
| Adaptation A | X | Standard Cable Entries |
| Adaptation B | X | No adaptation |
| Software Release | SXXX | Latest release std. SW. |
| Software Language Pack | X | Standard Language Pack |
| A Option | AQ | Modbus TCP MCA 122 |
| B Option | B4 | MCB-114 VLT Sensor Input |
| C0 Option MCO | CX | No C0 option |
| C1 Option | X | No C1 option |
| C Option Software | XX | No software option |
| D Option | DX | No D option |
| Frame Size | D5H | |
| Power 110% (NO) [KW] | 160 | |
| Height [mm] | 1324,0 | |
| Width w/ no C options [mm] | 325,0 | |
| Depth [mm] | 381,0 | |
| Depth with Option A/B [mm] | 381,0 | |
| kVA | 229 | |
| Power Loss NO [W] | 2646 | |
| Power Loss NO [W] | 2738 | |
| Continuous Current (NO) [A] | 201 | |
| Intermittent Current (NO) [A] | 221 | |
| Continuous Current (NO) [A] | 192 | |
| Intermittent Current (NO) [A] | 211 | |
| Power Rating at 525-550V | 132kW | |
| Power Rating at 575V | 200HP | |
| Power Rating at 690V | 160kW |
Technical data
| Motor power | 160 kW / 250 HP | |
| Mains voltage | 525 - 690 VAC * | |
| Phase | Three-phase | |
| Protection rating | IP21/Type 1+mains shield | |
| Frame size | D5H | |
| RFI filter | Class A2 (EMC C3) | |
| Brake chopper | No | |
| Safe Torque Off | Yes | |
| Control panel | Graphical LCP | |
| PCB coating | Coated PCB | |
| Mains option | Mains Disconnect + Fuse | |
| Fieldbus | Modbus TCP MCA 122 | |
| Product type | Frequency converter | |
| Continuous output current | 201 A | |
| Continuous current (high line) | 192 A | |
| Intermittent output current | 221 A | |
| Apparent power | 229 kVA | |
| Power loss | 2646 W | |
| Power, normal overload | 160 kW | |
| Height | 1324 mm | |
| Width | 325 mm | |
| Depth | 381 mm | |
| Depth with A/B options | 381 mm | |
| Net weight | 166 kg | |
| Gross weight | 166.3 kg | |
| EAN | 5715253755533 | |
| ECCN (EU) | Y901 | |
| ECCN (US) | 3A999.a | |
Documents
Operating guides, design guides, certificates and CAD drawings for 137U7055 are available on request. Ask for documents →
Other 160 kW / 250 HP variants in VLT HVAC Drive FC 102
- 134L4953 IP20 · Class A2 · D3H
- 136G4866 IP20 · Class A2 · D3H
- 137U4601 IP20 · Class A2 · D3H
- 134H7748 IP20 · Class A2 · D3H
- 134X4358 IP20 · Class A2 · D3H
- 134L9730 IP20 · Class A2 · D3H
- 134U6067 IP20 · Class A2 · D3H
- 137X6745 IP20 · Class A2 · D3H
- 136U3171 IP20 · Class A2 · D3H
- 135U2729 IP20 · Class A2 · D3H
- 134N1612 IP20 · Class A2 · D3H
- 134G9193 IP20 · Class A2 · D3H
- 134G8008 IP20 · Class A2 · D3H
- 134H1627 IP20 · Class A2 · D3H
- 134N1608 IP20 · Class A2 · D3H
- 137H8057 IP20 · Class A2 · D3H
- 134X3440 IP20 · Class A2 · D3H
- 134G7129 IP20 · Class A2 · D3H
- 134H8758 IP20 · Class A2 · D3H
- 134H7499 IP20 · Class A2 · D3H
- 136X7135 IP20 · Class A2 · D3H
- 134G7870 IP20 · Class A2 · D3H
- 136H3023 IP21 · Class A2 · D5H
- 134N1679 IP21 · Class A2 · D5H