Danfoss VLT HVAC Drive FC 102 FC-102P90KT4P55H3XGXXXXLX1XXAKBXCXXXXD1
137U8993

Danfoss 137U8993 - VLT HVAC Drive FC 102 (90 kW / 125 HP, IP55, 380-480V)

  • Frequency Converter
  • VLT® HVAC Drive FC-102
  • (P90K) 90 KW / 125 HP,
  • Three phase, 380 - 480 VAC,IP55 / Type12 Backplate
  • (H3) RFI Class A1/B (C1)
  • No brake chopper
  • Graphical Loc. Cont. Panel
  • Not coated PCB, No Mains Option
  • Condition Based Monitoring CBM
  • Frame: C2
  • MCA 125 BACnet/IP, No B Option
  • No C1 option, MCB-117 Real time clock option
Model code:
FC-102P90KT4P55H3XGXXXXLX1XXAKBXCXXXXD1
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® HVAC Drive FC-
Series102
Power RatingP90K(P90K) 90 KW / 125 HP
PhaseTThree phase
Mains Voltage4380 - 480 VAC
EnclosureP55IP55 / Type12 Backplate
RFI FilterH3(H3) RFI Class A1/B (C1)
Brake - Safe StopXNo brake chopper
LCPGGraphical Loc. Cont. Panel
Coating PCBXNot coated PCB
Mains OptionXNo Mains Option
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseLX1XCondition Based Monitoring CBM
Software Language PackXStandard Language Pack
A OptionAKMCA 125 BACnet/IP
B OptionBXNo B Option
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionD1MCB-117 Real time clock option
Frame SizeC2
Power 110% (NO) [KW]90
Height [mm]780,0
Width w/ no C options [mm]370,0
Depth [mm]332,0
Depth with Option A/B [mm]332,0
kVA123
Power Loss NO [W]1474
Continuous Current (NO) [A]177
Intermittent Current (NO) [A]195
Continuous Current (NO) [A]160
Intermittent Current (NO) [A]176

Technical data

Motor power90 kW / 125 HP
Mains voltage380 - 480 VAC
PhaseThree-phase
Protection ratingIP55 / Type12 Backplate
Frame sizeC2
RFI filterClass A1/B (EMC C1)
Brake chopperNo
Control panelGraphical LCP
PCB coatingUncoated
Mains optionNone
FieldbusMCA 125 BACnet/IP
Product typeFrequency converter
Continuous output current177 A
Continuous current (high line)160 A
Intermittent output current195 A
Apparent power123 kVA
Power loss1474 W
Power, normal overload90 kW
Height780 mm
Width370 mm
Depth332 mm
Depth with A/B options332 mm
Net weight60.69 kg
Gross weight64.03 kg
Packed volume228.1 L
EAN5715253775111
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 137U8993 are available on request. Ask for documents →

Other 90 kW / 125 HP variants in VLT HVAC Drive FC 102

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty

We only use your details to answer this request. See our privacy policy.