Danfoss VLT HVAC Drive FC 102 FC-102N132T4E54H4TGRXXXSXXXXALB0CXRXXD0
137X1628

Danfoss 137X1628 - VLT HVAC Drive FC 102 (132 kW / 200 HP, IP54, 380-480V)

  • Frequency Converter
  • VLT® HVAC Drive FC-102
  • (N132) 132 KW / 200 HP,
  • Three phase, 380 - 480 VAC,(E54) IP54 / Type 12
  • RFI class A1 (C2)
  • Safe Stop
  • Graphical Loc. Cont. Panel
  • Coated PCB 3C3 + Ruggedised, No Mains Option
  • Latest release std. SW.
  • Frame: D1H
  • PROFINET MCA 120, MCB-109 I/O, RTC Back-up
  • MCB-113 Ext. Relay Card, MCB-107 24V DC backup
Model code:
FC-102N132T4E54H4TGRXXXSXXXXALB0CXRXXD0
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® HVAC Drive FC-
Series102
Power RatingN132(N132) 132 KW / 200 HP
PhaseTThree phase
Mains Voltage4380 - 480 VAC
EnclosureE54(E54) IP54 / Type 12
RFI FilterH4RFI class A1 (C2)
Brake - Safe StopTSafe Stop
LCPGGraphical Loc. Cont. Panel
Coating PCBRCoated PCB 3C3 + Ruggedised
Mains OptionXNo Mains Option
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionALPROFINET MCA 120
B OptionB0MCB-109 I/O, RTC Back-up
C0 Option MCOCXNo C0 option
C1 OptionRMCB-113 Ext. Relay Card
C Option SoftwareXXNo software option
D OptionD0MCB-107 24V DC backup
Frame SizeD1H
Power 110% (NO) [KW]132
Height [mm]901,0
Width w/ no C options [mm]325,0
Depth [mm]378,0
Depth with Option A/B [mm]378,0
kVA180
Power Loss NO [W]2949
Power Loss NO [W]2719
Continuous Current (NO) [A]260
Intermittent Current (NO) [A]286
Continuous Current (NO) [A]240
Intermittent Current (NO) [A]264

Technical data

Motor power132 kW / 200 HP
Mains voltage380 - 480 VAC
PhaseThree-phase
Protection ratingIP54 / Type 12
Frame sizeD1H
RFI filterClass A1 (EMC C2)
Brake chopperNo
Safe Torque OffYes
Control panelGraphical LCP
PCB coatingCoated PCB 3C3 + Ruggedised
Mains optionNone
FieldbusPROFINET MCA 120
Product typeFrequency converter
Continuous output current260 A
Continuous current (high line)240 A
Intermittent output current286 A
Apparent power180 kVA
Power loss2949 W
Power, normal overload132 kW
Height901 mm
Width325 mm
Depth378 mm
Depth with A/B options378 mm
Net weight62 kg
Gross weight62.3 kg
EAN5715253802633
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 137X1628 are available on request. Ask for documents →

Other 132 kW / 200 HP variants in VLT HVAC Drive FC 102

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty

We only use your details to answer this request. See our privacy policy.