137X1977
Danfoss 137X1977 - VLT AutomationDrive FC 302 (160 kW / 250 HP, IP54, 380-500V)
- Frequency converter
- VLT® AutomationDrive FC-302
- (N160) 160 KW / 250 HP,
- Three phase, 380 - 500 VAC,IP54/Type 12+main shield
- RFI class A1 (C2)
- Brake chopper
- Graphical Loc. Cont. Panel
- Coated PCB, Mains Disconnect + Fuse
- Latest release std. SW.
- Frame: D7H
- PROFINET MCA 120, No B Option
- No C1 option, MCB-107 24V DC backup
Model code:
FC-302N160T5E5MH4BGC3XXSXXXXALBXCXXXXD0
FC-302N160T5E5MH4BGC3XXSXXXXALBXCXXXXD0
Similar products
- Genuine Danfoss products
- Danfoss manufacturer warranty
- Reply within one business day
Product details
| Product Group | FC- | VLT® AutomationDrive FC- |
| Series | 302 | |
| Power Rating | N160 | (N160) 160 KW / 250 HP |
| Phase | T | Three phase |
| Mains Voltage | 5 | 380 - 500 VAC |
| Enclosure | E5M | IP54/Type 12+main shield |
| RFI Filter | H4 | RFI class A1 (C2) |
| Brake - Safe Stop | B | Brake chopper |
| LCP | G | Graphical Loc. Cont. Panel |
| Coating PCB | C | Coated PCB |
| Mains Option | 3 | Mains Disconnect + Fuse |
| Adaptation A | X | Standard Cable Entries |
| Adaptation B | X | No adaptation |
| Software Release | SXXX | Latest release std. SW. |
| Software Language Pack | X | Standard Language Pack |
| A Option | AL | PROFINET MCA 120 |
| B Option | BX | No B Option |
| C0 Option MCO | CX | No C0 option |
| C1 Option | X | No C1 option |
| C Option Software | XX | No software option |
| D Option | D0 | MCB-107 24V DC backup |
| Frame Size | D7H | |
| Power 150% (HO) [KW] | 160 | |
| Power 110% (NO) [KW] | 200 | |
| Height [mm] | 1978,0 | |
| Width w/ no C options [mm] | 420,0 | |
| Depth [mm] | 386,0 | |
| Depth with Option A/B [mm] | 386,0 | |
| kVA | 218 | |
| Continuous Current (NO) [A] | 395 | |
| Intermittent Current (NO) [A] | 435 | |
| Continuous Current (NO) [A] | 361 | |
| Intermittent Current (NO) [A] | 397 | |
| Continuous Current (HO) [A] | 315 | |
| Intermittent Current (HO) [A] | 472 | |
| Continuous Current (HO) [A] | 302 | |
| Intermittent Current (HO) [A] | 453 |
Technical data
| Motor power | 160 kW / 250 HP | |
| Mains voltage | 380 - 500 VAC | |
| Phase | Three-phase | |
| Protection rating | IP54/Type 12+main shield | |
| Frame size | D7H | |
| RFI filter | Class A1 (EMC C2) | |
| Brake chopper | Yes | |
| Safe Torque Off | Yes | |
| Control panel | Graphical LCP | |
| PCB coating | Coated PCB | |
| Mains option | Mains Disconnect + Fuse | |
| Fieldbus | PROFINET MCA 120 | |
| Product type | Frequency converter | |
| Continuous output current | 395 A | |
| Continuous current (high line) | 361 A | |
| Intermittent output current | 435 A | |
| Continuous current (high overload) | 315 A | |
| Apparent power | 218 kVA | |
| Power, normal overload | 200 kW | |
| Power, high overload | 160 kW | |
| Height | 1978 mm | |
| Width | 420 mm | |
| Depth | 386 mm | |
| Depth with A/B options | 386 mm | |
| Net weight | 200 kg | |
| Gross weight | 200.3 kg | |
| EAN | 5715253806266 | |
| ECCN (EU) | Y901 | |
| ECCN (US) | 3A999.a | |
Documents
Operating guides, design guides, certificates and CAD drawings for 137X1977 are available on request. Ask for documents →
Other 160 kW / 250 HP variants in VLT AutomationDrive FC 302
- 137H5148 IP20 · Class A2 · D4H
- 137U2936 IP20 · Class A2 · D4H
- 134X2814 IP20 · Class A2 · D4H
- 134U3275 IP20 · Class A2 · D4H
- 132X5274 IP20 · Class A2 · D4H
- 134N0169 IP20 · Class A2 · D4H
- 136F8859 IP20 · Class A2 · D4H
- 134N7783 IP20 · Class A2 · D4H
- 136N6690 IP20 · Class A2 · D4H
- 134N7782 IP20 · Class A2 · D4H
- 134U1736 IP20 · Class A2 · D4H
- 134N8875 IP20 · Class A2 · D4H
- 134U7150 IP20 · Class A2 · D4H
- 132L9917 IP20 · Class A2 · D4H
- 134H8934 IP20 · Class A2 · D4H
- 134L2737 IP20 · Class A2 · D4H
- 134N4294 IP20 · Class A2 · D4H
- 137L3602 IP20 · Class A2 · D4H
- 136F2443 IP20 · Class A2 · D4H
- 136F9821 IP20 · Class A2 · D4H
- 134L1024 IP20 · Class A2 · D4H
- 134L0138 IP20 · Class A2 · D4H
- 134L7863 IP20 · Class A2 · D4H
- 134L1610 IP20 · Class A2 · D4H