Danfoss VLT AutomationDrive FC 302 FC-302N90KT7E20H2XGCXXXSXXXXANB2CXXXXD0
137X9354

Danfoss 137X9354 - VLT AutomationDrive FC 302 (90 kW / 125 HP, IP20, 525-690V)

  • Frequency converter
  • VLT® AutomationDrive FC-302
  • (N90K) 90 KW / 125 HP, 75kW@525- 550V, 100HP@575V, 90kW@690V
  • Three phase, 525 - 690 VAC *, (E20) IP20 / Chassis
  • RFI Filter
  • No brake chopper
  • Graphical Loc. Cont. Panel
  • Coated PCB, No Mains Option
  • Latest release std. SW.
  • Frame: D3H
  • EtherNet/IP MCA 121, MCB-112 PTC Therm. Card
  • No C1 option, MCB-107 24V DC backup
  • ATEX: II (2) G [Ex eb Gb] [Ex db Gb] / II (2) D [Ex tb Db]
Model code:
FC-302N90KT7E20H2XGCXXXSXXXXANB2CXXXXD0
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® AutomationDrive FC-
Series302
Power RatingN90K(N90K) 90 KW / 125 HP
PhaseTThree phase
Mains Voltage7525 - 690 VAC *
EnclosureE20(E20) IP20 / Chassis
RFI FilterH2RFI Filter
Brake - Safe StopXNo brake chopper
LCPGGraphical Loc. Cont. Panel
Coating PCBCCoated PCB
Mains OptionXNo Mains Option
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
B OptionB2MCB-112 PTC Therm. Card
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionD0MCB-107 24V DC backup
Frame SizeD3H
Power 150% (HO) [KW]90
Power 110% (NO) [KW]110
Power Loss HO [W]1430
Power Loss HO [W]1480
Power Loss NO [W]1798
Power Loss NO [W]1740
kVA129
Continuous Current (HO) [A]113
Intermittent Current (HO) [A]170
Continuous Current (HO) [A]108
Continuous Current (NO) [A]131
Intermittent Current (HO) [A]162
Intermittent Current (NO) [A]151
Continuous Current (NO) [A]137
Intermittent Current (NO) [A]144
Height [mm]909,0
Height w/ Regen/Loadshare [mm]1004,0
Width w/ no C options [mm]250,0
Depth [mm]375,0
Depth with Option A/B [mm]375,0
ATEX Marking 1ATEX: II (2) G [Ex eb Gb] [Ex
ATEX Marking 2db Gb] / II (2) D [Ex tb Db]
Power Rating at 525-550V75kW
Power Rating at 575V100HP
Power Rating at 690V90kW

Technical data

Motor power90 kW / 125 HP
Mains voltage525 - 690 VAC *
PhaseThree-phase
Protection ratingIP20 / Chassis
Frame sizeD3H
RFI filterClass A2 (EMC C3)
Brake chopperNo
Safe Torque OffYes
Control panelGraphical LCP
PCB coatingCoated PCB
Mains optionNone
Product typeFrequency converter
Continuous output current131 A
Continuous current (high line)137 A
Intermittent output current151 A
Continuous current (high overload)113 A
Apparent power129 kVA
Power loss1798 W
Power, normal overload110 kW
Power, high overload90 kW
Height909 mm
Height with regen/loadshare1004 mm
Width250 mm
Depth375 mm
Depth with A/B options375 mm
Net weight62 kg
Gross weight62.3 kg
Packed volume255.9 L
EAN5715253881188
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 137X9354 are available on request. Ask for documents →

Other 90 kW / 125 HP variants in VLT AutomationDrive FC 302

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty

We only use your details to answer this request. See our privacy policy.