Danfoss VLT HVAC Drive FC 102 FC-102N160T7E54H2TGC3XQSXXXXAXBXCXXXXDX
167F0845

Danfoss 167F0845 - VLT HVAC Drive FC 102 (160 kW / 250 HP, IP54, 525-690V)

  • Frequency Converter
  • VLT® HVAC Drive FC-102
  • (N160) 160 KW / 250 HP, 132kW@525- 550V, 200HP@575V, 160kW@690V
  • Three phase, 525 - 690 VAC *, (E54) IP54 / Type 12
  • RFI Filter
  • Safe Stop
  • Graphical Loc. Cont. Panel
  • Coated PCB, Mains Disconnect + Fuse
  • Latest release std. SW.
  • Frame: D5H
  • No A Option, No B Option
  • No C1 option, No D option
Model code:
FC-102N160T7E54H2TGC3XQSXXXXAXBXCXXXXDX
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® HVAC Drive FC-
Series102
Power RatingN160(N160) 160 KW / 250 HP
PhaseTThree phase
Mains Voltage7525 - 690 VAC *
EnclosureE54(E54) IP54 / Type 12
RFI FilterH2RFI Filter
Brake - Safe StopTSafe Stop
LCPGGraphical Loc. Cont. Panel
Coating PCBCCoated PCB
Mains Option3Mains Disconnect + Fuse
Adaptation AXStandard Cable Entries
Adaptation BQHeat-sink access
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
B OptionBXNo B Option
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionDXNo D option
Frame SizeD5H
Height [mm]1324,0
Width w/ no C options [mm]325,0
Depth [mm]381,0
Depth with Option A/B [mm]381,0
Power 110% (NO) [KW]160
kVA229
Power Loss NO [W]2646
Power Loss NO [W]2738
Continuous Current (NO) [A]201
Intermittent Current (NO) [A]221
Continuous Current (NO) [A]192
Intermittent Current (NO) [A]211
Power Rating at 525-550V132kW
Power Rating at 575V200HP
Power Rating at 690V160kW

Technical data

Motor power160 kW / 250 HP
Mains voltage525 - 690 VAC *
PhaseThree-phase
Protection ratingIP54 / Type 12
Frame sizeD5H
RFI filterClass A2 (EMC C3)
Brake chopperNo
Safe Torque OffYes
Control panelGraphical LCP
PCB coatingCoated PCB
Mains optionMains Disconnect + Fuse
Product typeFrequency converter
Continuous output current201 A
Continuous current (high line)192 A
Intermittent output current221 A
Apparent power229 kVA
Power loss2646 W
Power, normal overload160 kW
Height1324 mm
Width325 mm
Depth381 mm
Depth with A/B options381 mm
Net weight166 kg
Gross weight166.3 kg
Packed volume587.7 L
EAN5715253896588
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 167F0845 are available on request. Ask for documents →

Other 160 kW / 250 HP variants in VLT HVAC Drive FC 102

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery

We only use your details to answer this request. See our privacy policy.