167F2571
Danfoss 167F2571 - iC7-Marine System Modules (1100 kW / 1500 HP, IP00, 525-690V)
- iC7-Marine
- System module, liquid-cooled
- IC7-60SLIN07-1230E00F4+AE10+AFMC+AKFX+ANN1 +AONH+BAMT+BDC1+BEF2+BF20+BGK1+BH25+BK50+BL50+CAR0 +DAMA +EGIN+EHEN
- IP00/Open Type, Frame: 2xIR12L
- Inverter module, INU, 525-690 V AC / 640-1100 V DC, 1230 A
- EMC category: C4 category
- Control Panel 2.8 OPX20
- Standard I/O: I/O and Relay Option OC7C1
- Modbus TCP OS7MT
- Functional Safety: STO, SS1-t
Model code:
IC7-60SLIN07-1230E00F4+AE10+AFMC+AKFX+ANN1+AONH+BAMT+BDC1+BEF2+BF20+BGK1+BH25+BK50+BL50+CAR0+DAMA+EGIN+EHEN
IC7-60SLIN07-1230E00F4+AE10+AFMC+AKFX+ANN1+AONH+BAMT+BDC1+BEF2+BF20+BGK1+BH25+BK50+BL50+CAR0+DAMA+EGIN+EHEN
Similar products
- Genuine Danfoss products
- Danfoss manufacturer warranty
- Reply within one business day
Product details
| Product series | +DAMA | iC7-Marine |
| Product group | IC7-60 | iC7-60 |
| Product category | SL | System module, liquid-cooled |
| Product type | IN | Inverter module, INU |
| Mains voltage | 07 | 525-690 V AC / 640-1100 V DC |
| Current rating | -1230 | 1230 A |
| Power rating | 1M1 | 1.1 MW/1500 HP |
| Protection rating | E00 | IP00/Open Type |
| EMC category | F4 | C4 category |
| Integration unit | +AE10 | Standard, no filter |
| Mains input device | +AJXX | None |
| DC fuses and devices | +AKFX | DC bus fuses |
| Cooling circuit connector type | +ANN1 | Push-in connection |
| Cooling circuit hose length | +AONH | None |
| Marine construction | +AFMC | Power terminal adapter |
| Extra environmental protection | +AGCX | Coated boards |
| Communication interface, X1/X2 | +BAMT | Modbus TCP OS7MT |
| Communication interface, X0 | +BBEL | Ethernet port, no protocol |
| Standard I/O | +BDC1 | I/O and Relay Option OC7C1 |
| Functional safety | +BEF2 | STO, SS1-t |
| Control panel | +BF20 | Control Panel 2.8 OPX20 |
| Control panel mounting type | +BGK1 | Flush mount |
| Control panel cable length | +BH25 | 2.5 m (8 ft) |
| Control unit cable length | +BK50 | 5.0 m (16 ft), Fiber |
| StarCoupler board cable length | +BL50 | 5.0 m (16 ft), Fiber |
| Option slot A | +CAR0 | Relay Option OC7R0 |
| Option slot B | +CBXX | None, without mounting plate |
| Option slot C | +CCXX | None, without mounting plate |
| Option slot D | +CDXX | None, without mounting plate |
| Option slot E | +CEXX | None, without mounting plate |
| Option slot F | +CFXX | None, without mounting plate |
| Option slot G | +CGXX | None, without mounting plate |
| Option slot H | +CHXX | None, without mounting plate |
| Option slot I | +CIXX | None, without mounting plate |
| Option slot J | +CJXX | None, without mounting plate |
| Language package | +EL01 | Global |
| Customer specific application | +DBXX | None |
| Additional drive features 1 | +DD1X | None |
| Additional drive features 2 | +DE2X | None |
| Additional drive features 3 | +DF3X | None |
| Additional drive features 4 | +DG4X | None |
| Additional drive features 5 | +DH5X | None |
| High speed enabled | +DI6X | No |
| Customization file package ID | +EAXXXXXX | No customization |
| Product software ID | +ECXXX | Latest released version |
| Technical documentation | +EGIN | Installation guide |
| Documentation language | +EHEN | English |
| Customer-specific label | +EJXX | None |
| Shipping package | +TACB | Cardboard box package |
| Product specific marine cert. | +VBXX | None |
| Frame designation | 2XIR12L | 2xIR12L |
| Main unit Width | 2x235mm/9.3in | |
| Main unit Height | 1295mm/51in | |
| Main unit Depth | 566mm/22.3in | |
| AC voltage | 3X0-575/600/690VAC | |
| Continous current IL (1/5min) | 1230A | |
| Cooling type | Liquid Cooled | |
| DC Bus current | 1295A(932VDC) | |
| DC Bus voltage | 640-1100VDC | |
| DC power | 1206kW(932VDC) | |
| Liquid temp. High Overload | 45°C/113°F | |
| Liquid temp. Low Overload | 45°C/113°F | |
| Liquid temp. Nominal load | 45°C/113°F | |
| Nominal AC current | 1256A | |
| Overload current IL (1/5min) | 1353A | |
| Start current Imax (3sec) | 1844A | |
| Storage temperature | -40...70°C/-40...158°F |
Technical data
| Motor power | 1100 kW / 1500 HP | |
| Mains voltage | 525-690 V AC / 640-1100 V DC | |
| Protection rating | IP00/Open Type | |
| Frame size | 2xIR12L | |
| RFI filter | None (EMC C4) | |
| Safe Torque Off | Yes | |
| Control panel | Control Panel 2.8 (OPX20) | |
| PCB coating | Coated PCB | |
| Mains option | None | |
| Fieldbus | Modbus TCP OS7MT | |
| Product type | System module, liquid-cooled (Inverter module, INU) | |
| Continuous output current | 1230 A | |
| Intermittent output current | 1353 A | |
| Rated current | 1230 A | |
| Standard I/O | I/O and Relay Option OC7C1 | |
| Height | 1295 mm | |
| Depth | 566 mm | |
| Net weight | 250 kg | |
| Gross weight | 334 kg | |
| Packed volume | 1031 L | |
| EAN | 5715253914848 | |
| ECCN (US) | 3A999.a | |
Documents
Operating guides, design guides, certificates and CAD drawings for 167F2571 are available on request. Ask for documents →
Other 1100 kW / 1500 HP variants in iC7-Marine System Modules
- 137H6567 IP00 · None · 2xIR12L
- 137U7360 IP00 · None · 2xIR12L
- 167F2543 IP00 · None · 2xIR12L
- 137X7018 IP00 · None · 2xIR12L
- 167F9526 IP00 · None · 2xIR12L
- 137U3490 IP00 · None · 2xIR12L
- 137H5009 IP00 · None · 2xIR12L
- 137U0625 IP00 · None · 2xIR12L
- 167F8567 IP00 · None · 2xIR12L
- 137X4770 IP00 · None · 2xIR12L
- 137N7202 IP00 · None · 2xIR12L
- 137N7230 IP00 · None · 2xIR12L
- 137X5932 IP00 · None · 2xIR12L
- 137N8018 IP00 · None · 2xIR12L
- 137N6702 IP00 · None · 2xIR12L
- 137X5837 IP00 · None · 2xIR12L
- 167F7438 IP00 · None · 2xIR12L
- 167F8857 IP00 · None · 2xIR12L
- 167G3548 IP00 · None · 2xIR12L