Danfoss VLT HVAC Drive FC 102 FC-102P45KT4E55H1TGC1XXSXXXXAXB2CXXXXD0
167F4270

Danfoss 167F4270 - VLT HVAC Drive FC 102 (45 kW / 60 HP, IP55, 380-480V)

  • Frequency Converter
  • VLT® HVAC Drive FC-102
  • (P45K) 45 KW / 60 HP,
  • Three phase, 380 - 480 VAC, IP55 / Type 12
  • (H1) RFI Class A1/B (C1)
  • Safe Stop
  • Graphical Loc. Cont. Panel
  • Coated PCB, Mains Disconnect
  • Latest release std. SW.
  • Frame: C1
  • No A Option, MCB-112 PTC Therm. Card
  • No C1 option, MCB-107 24V DC backup
  • ATEX: II (2) G [Ex eb Gb] [Ex db Gb] / II (2) D [Ex tb Db]
Model code:
FC-102P45KT4E55H1TGC1XXSXXXXAXB2CXXXXD0
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® HVAC Drive FC-
Series102
Power RatingP45K(P45K) 45 KW / 60 HP
PhaseTThree phase
Mains Voltage4380 - 480 VAC
EnclosureE55IP55 / Type 12
RFI FilterH1(H1) RFI Class A1/B (C1)
Brake - Safe StopTSafe Stop
LCPGGraphical Loc. Cont. Panel
Coating PCBCCoated PCB
Mains Option1Mains Disconnect
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
B OptionB2MCB-112 PTC Therm. Card
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionD0MCB-107 24V DC backup
Frame SizeC1
Height [mm]685,0
Width w/ no C options [mm]308,0
Depth [mm]311,0
Depth with Option A/B [mm]311,0
Power 110% (NO) [KW]45
kVA62.4
Power Loss NO [W]843
Continuous Current (NO) [A]90
Intermittent Current (NO) [A]99
Continuous Current (NO) [A]80
Intermittent Current (NO) [A]88
ATEX Marking 1ATEX: II (2) G [Ex eb Gb] [Ex
ATEX Marking 2db Gb] / II (2) D [Ex tb Db]

Technical data

Motor power45 kW / 60 HP
Mains voltage380 - 480 VAC
PhaseThree-phase
Protection ratingIP55 / Type 12
Frame sizeC1
RFI filterClass A1/B (EMC C1)
Brake chopperNo
Safe Torque OffYes
Control panelGraphical LCP
PCB coatingCoated PCB
Mains optionMains Disconnect
Product typeFrequency converter
Continuous output current90 A
Continuous current (high line)80 A
Intermittent output current99 A
Apparent power62.4 kVA
Power loss843 W
Power, normal overload45 kW
Height685 mm
Width308 mm
Depth311 mm
Depth with A/B options311 mm
Net weight41.41 kg
Gross weight44.41 kg
Packed volume158.1 L
EAN5715253932811
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 167F4270 are available on request. Ask for documents →

Other 45 kW / 60 HP variants in VLT HVAC Drive FC 102

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery

We only use your details to answer this request. See our privacy policy.