Danfoss VLT Refrigeration Drive FC 103 FC-103N250T4E54H2XGC3XXSXXXXALBXCXXXXD1
167F5138

Danfoss 167F5138 - VLT Refrigeration Drive FC 103 (250 kW / 350 HP, IP54, 380-480V)

  • Frequency converter
  • VLT® Refrigeration Drive FC-103
  • (N250) 250 KW / 350 HP,
  • Three phase, 380 - 480 VAC, (E54) IP54 / Type 12
  • RFI filter Class A2
  • No brake chopper
  • Graphical Loc. Cont. Panel
  • Coated PCB, Mains Disconnect + Fuse
  • No adaptation
  • Latest release std. SW.
  • PROFINET MCA 120, No B Option
  • No C1 option, MCB-117 Real time clock option
  • Frame: D7H
Model code:
FC-103N250T4E54H2XGC3XXSXXXXALBXCXXXXD1
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® Refrigeration Drive
Series103
Power RatingN250(N250) 250 KW / 350 HP
PhaseTThree phase
Mains Voltage4380 - 480 VAC
EnclosureE54(E54) IP54 / Type 12
RFI FilterH2RFI filter Class A2
Brake - Safe StopXNo brake chopper
LCPGGraphical Loc. Cont. Panel
Coating PCBCCoated PCB
Mains Option3Mains Disconnect + Fuse
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionALPROFINET MCA 120
B OptionBXNo B Option
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionD1MCB-117 Real time clock option
Frame SizeD7H
Power 110% (NO) [KW]250
kVA333
Power Loss NO [W]5129
Power Loss NO [W]4558
Continuous Current (NO) [A]480
Intermittent Current (NO) [A]528
Continuous Current (NO) [A]443
Intermittent Current (NO) [A]487
Height [mm]1978,0
Width w/ no C options [mm]420,0
Depth [mm]386,0
Depth with Option A/B [mm]386,0

Technical data

Motor power250 kW / 350 HP
Mains voltage380 - 480 VAC
PhaseThree-phase
Protection ratingIP54 / Type 12
Frame sizeD7H
RFI filterClass A2 (EMC C3)
Brake chopperNo
Control panelGraphical LCP
PCB coatingCoated PCB
Mains optionMains Disconnect + Fuse
FieldbusPROFINET MCA 120
Product typeFrequency converter
Continuous output current480 A
Continuous current (high line)443 A
Intermittent output current528 A
Apparent power333 kVA
Power loss5129 W
Power, normal overload250 kW
Height1978 mm
Width420 mm
Depth386 mm
Depth with A/B options386 mm
Net weight200 kg
Gross weight200.3 kg
Packed volume956.2 L
EAN5715253942391
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 167F5138 are available on request. Ask for documents →

Other 250 kW / 350 HP variants in VLT Refrigeration Drive FC 103

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery

We only use your details to answer this request. See our privacy policy.