Danfoss VLT HVAC Drive FC 102 FC-102P45KT7E20H4UGCXXXSXXXXALB4CXXXXD0
167F5244

Danfoss 167F5244 - VLT HVAC Drive FC 102 (45 kW / 60 HP, IP20, 525-690V)

  • Frequency Converter
  • VLT® HVAC Drive FC-102
  • (P45K) 45 KW / 60 HP, 37kW@525- 550V, 50HP@575V, 45kW@690V
  • Three phase, 525 - 690 VAC *, (E20) IP20 / Chassis
  • RFI class A1 (C2)
  • Brake chopper + Safe stop
  • Graphical Loc. Cont. Panel
  • Coated PCB, No Mains Option
  • Latest release std. SW.
  • Frame: C3
  • PROFINET MCA 120, MCB-114 VLT Sensor Input
  • No C1 option, MCB-107 24V DC backup
Model code:
FC-102P45KT7E20H4UGCXXXSXXXXALB4CXXXXD0
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® HVAC Drive FC-
Series102
Power RatingP45K(P45K) 45 KW / 60 HP
PhaseTThree phase
Mains Voltage7525 - 690 VAC *
EnclosureE20(E20) IP20 / Chassis
RFI FilterH4RFI class A1 (C2)
Brake - Safe StopUBrake chopper + Safe stop
LCPGGraphical Loc. Cont. Panel
Coating PCBCCoated PCB
Mains OptionXNo Mains Option
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
B OptionB4MCB-114 VLT Sensor Input
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionD0MCB-107 24V DC backup
Frame SizeC3
Height [mm]550,0
Width w/ no C options [mm]308,0
Depth [mm]333,0
Depth with Option A/B [mm]333,0
Power 110% (NO) [KW]45
kVA62.1
Power Loss NO [W]592
Continuous Current (NO) [A]54
Intermittent Current (NO) [A]59.4
Continuous Current (NO) [A]52
Intermittent Current (NO) [A]57.2
Power Rating at 525-550V37kW
Power Rating at 575V50HP
Power Rating at 690V45kW

Technical data

Motor power45 kW / 60 HP
Mains voltage525 - 690 VAC *
PhaseThree-phase
Protection ratingIP20 / Chassis
Frame sizeC3
RFI filterClass A1 (EMC C2)
Brake chopperYes
Safe Torque OffYes
Control panelGraphical LCP
PCB coatingCoated PCB
Mains optionNone
Product typeFrequency converter
Continuous output current54 A
Continuous current (high line)52 A
Intermittent output current59.4 A
Apparent power62.1 kVA
Power loss592 W
Power, normal overload45 kW
Height550 mm
Width308 mm
Depth333 mm
Depth with A/B options333 mm
Net weight36.46 kg
Gross weight39.31 kg
Packed volume158.1 L
EAN5715253943459
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 167F5244 are available on request. Ask for documents →

Other 45 kW / 60 HP variants in VLT HVAC Drive FC 102

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery

We only use your details to answer this request. See our privacy policy.