167F5531
Danfoss 167F5531 - iC7 Automation Enclosed Drives (200 kW / 300 HP, IP54, 380-500V)
- iC7-Automation
- Enclosed drive, air-cooled
- IC7-60EA3H05-385AE54F3+BAIP +BEF2+DAAU +EGXX +GACO+IFCS+IHAT +KCIT+KDOT+KDOT
- IP54/UL Type 12, Frame: AE10+IE10
- 3~, low-harmonic drive, 380-500 V AC, 385 A
- EMC Category: C3 category
- Control Panel 2.8 OPX20
- Standard I/O: I/O and Relay Option OC7C1
- EtherNet/IP OS7IP
- Functional Safety: STO, SS1-t, fieldbus
Model code:
IC7-60EA3H05-385AE54F3+BAIP+BEF2+DAAU+EGXX+GACO+IFCS+IHAT+KCIT+KDOT+KDOT
IC7-60EA3H05-385AE54F3+BAIP+BEF2+DAAU+EGXX+GACO+IFCS+IHAT+KCIT+KDOT+KDOT
Similar products
- Genuine Danfoss products
- Danfoss manufacturer warranty
- Reply within one business day
Product details
| Product series | +DAAU | iC7-Automation |
| Product group | IC7-60 | iC7-60 |
| Product category | EA | Enclosed drive, air-cooled |
| Product type | 3H | 3~, low-harmonic drive |
| Mains voltage | 05 | 380-500 V AC |
| Current rating | -385A | 385 A |
| Power rating | 200 | 200 kW/300 HP |
| Protection rating | E54 | IP54/UL Type 12 |
| EMC category | F3 | C3 category |
| Integrated brake chopper | +ACXX | None |
| Marine construction | +AFXX | None |
| Extra environmental protection | +AGCX | Coated boards |
| Communication interface, X1/X2 | +BAIP | EtherNet/IP OS7IP |
| Communication interface, X0 | +BBEL | Ethernet port, no protocol |
| Standard I/O | +BDC1 | I/O and Relay Option OC7C1 |
| Functional safety | +BEF2 | STO, SS1-t, fieldbus |
| Control panel | +BF20 | Control Panel 2.8 OPX20 |
| Option slot A | +CAX0 | None |
| Option slot B | +CBX0 | None |
| Option slot C | +CCX0 | None |
| Option slot D | +CDX0 | None |
| Option slot E | +CEX0 | None |
| Option slot F | +CFX0 | None |
| Customer specific application | +DBXX | None |
| Additional drive features 1 | +DD1X | None |
| Additional drive features 2 | +DE2X | None |
| Additional drive features 3 | +DF3X | None |
| Additional drive features 4 | +DG4X | None |
| Additional drive features 5 | +DH5X | None |
| High speed enabled | +DI6X | No |
| Customization file package ID | +EAXXXXXX | No customization |
| Product software ID | +ECXXX | Latest released version |
| Technical documentation | +EGXX | None |
| Documentation language | +EHXX | Multi-language |
| Customer-specific label | +EJXX | None |
| Language package | +EL01 | Global |
| Shipping package | +TAWP | Wooden package |
| Mains input device | +GACO | Mains contactor and switch |
| Grounding Device Provision | +GCXX | None |
| Motor heater control | +IAXX | None |
| Cabinet heater | +IBXX | None |
| Motor fan control | +ICXX | None |
| Motor brake control | +IDXX | None |
| Control Power Supply | +IFCS | 24 VDC |
| Service socket | +IGXX | None |
| Auxillary voltage supply | +IHAT | AC voltage transformer |
| Door Signal lights | +IIXX | None |
| Customer control terminals | +IKXX | Spring-type, standard |
| Emergency stop push button | +ILXX | None |
| Insulation monitoring | +IMXX | None |
| Arc detection device | +INXX | None |
| Busbar input | +KAXX | None |
| DC terminals | +KBXX | None |
| Mains cabling direction | +KCIT | Top-entry |
| Motor cabling direction | +KDOT | Top-entry |
| Common motor output terminals | +KEXX | None |
| Cable entry plate | +KFXX | With standard glands |
| Cabinet sequencing | +KGXX | Left to right |
| Door mounting | +KHXX | Hinges on the right side |
| Output filter | +MAXX | None |
| Additional cabinets | +NAXX | None |
| Air-cooling options | +OAXX | Standard |
| Power unit service beam | +QAXX | None |
| UL compliance | +VAXX | No additional approvals |
| Product specific marine cert. | +VBXX | None |
| Customer specific option | +VNXX | None |
| Frame designation | A10C10 | AE10+IE10 |
| Continous current IL (1/5min) | 385A(400VAC)/364A(460VAC) | |
| Cooling type | Air cooled | |
| Input current in Low Overload | 303A(400VAC)/317A(480VAC) | |
| Main unit Depth [mm] | 685 | |
| Main unit Height [mm] | 2305 | |
| Main unit Width [mm] | 1208 | |
| Storage temperature | -40...+70°C |
Technical data
| Motor power | 200 kW / 300 HP | |
| Mains voltage | 380-500 V AC | |
| Phase | Three-phase | |
| Protection rating | IP54/UL Type 12 | |
| Frame size | AE10+IE10 | |
| RFI filter | Class A2 (EMC C3) | |
| Brake chopper | No | |
| Safe Torque Off | Yes | |
| Control panel | Control Panel 2.8 (OPX20) | |
| PCB coating | Coated PCB | |
| Mains option | Mains contactor and switch | |
| Fieldbus | EtherNet/IP OS7IP | |
| Product type | Enclosed drive | |
| Continuous output current | 385 A | |
| Rated current | 385 A | |
| Standard I/O | I/O and Relay Option OC7C1 | |
| Net weight | 690 kg | |
| Gross weight | 970 kg | |
| EAN | 5715253946856 | |
| ECCN (US) | 3A999.a | |
Documents
Operating guides, design guides, certificates and CAD drawings for 167F5531 are available on request. Ask for documents →
Other 200 kW / 300 HP variants in iC7 Automation Enclosed Drives
- 167F7346 IP21 · Class A2 · AE10+IE10
- 137U8199 IP21 · Class A2 · AE10+IE10
- 137X0455 IP21 · Class A2 · AE10+IE10
- 137X5782 IP21 · Class A2 · AE10+IE10
- 137U0880 IP21 · Class A2 · AE10+IE10
- 167F7966 IP21 · Class A2 · AE10+IE10
- 167F2240 IP21 · Class A2 · AE10+IE10
- 167G0804 IP21 · Class A2 · AE10+IE10
- 137X7973 IP21 · Class A2 · AE10+IE10
- 137X7496 IP21 · Class A2 · AE10+IE10
- 137U5935 IP21 · Class A2 · AE10+IE10
- 167G2258 IP21 · Class A2 · AE10+IE10
- 167G2255 IP21 · Class A2 · AE10+IE10
- 167F0531 IP21 · Class A2 · AE10+IE10
- 167G9990 IP21 · Class A2 · AE10+IE10
- 167F6602 IP21 · Class A2 · AE10+IE10
- 167G3607 IP21 · Class A2 · AE10+IE10
- 167G7177 IP21 · Class A2 · AE10+IE10
- 137X2558 IP21 · Class A2 · AE10+IE10
- 167G3648 IP21 · Class A2 · AE10+IE10
- 167G4832 IP21 · Class A2 · AE10+IE10
- 167H0267 IP21 · Class A2 · AE10+IE10
- 167G7481 IP21 · Class A2 · AE10+IE10
- 137X0795 IP21 · Class A2 · AE10+IE10