Danfoss VLT HVAC Drive FC 102 FC-102N110T4E20H2TGC7XQSXXXXAXB2CXXXXD0
167F6855

Danfoss 167F6855 - VLT HVAC Drive FC 102 (110 kW / 150 HP, IP20, 380-480V)

  • Frequency Converter
  • VLT® HVAC Drive FC-102
  • (N110) 110 KW / 150 HP,
  • Three phase, 380 - 480 VAC, (E20) IP20 / Chassis
  • RFI Filter
  • Safe Stop
  • Graphical Loc. Cont. Panel
  • Coated PCB, Fuse
  • Latest release std. SW.
  • Frame: D3H
  • No A Option, MCB-112 PTC Therm. Card
  • No C1 option, MCB-107 24V DC backup
  • ATEX: II (2) G [Ex eb Gb] [Ex db Gb] / II (2) D [Ex tb Db]
Model code:
FC-102N110T4E20H2TGC7XQSXXXXAXB2CXXXXD0
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® HVAC Drive FC-
Series102
Power RatingN110(N110) 110 KW / 150 HP
PhaseTThree phase
Mains Voltage4380 - 480 VAC
EnclosureE20(E20) IP20 / Chassis
RFI FilterH2RFI Filter
Brake - Safe StopTSafe Stop
LCPGGraphical Loc. Cont. Panel
Coating PCBCCoated PCB
Mains Option7Fuse
Adaptation AXStandard Cable Entries
Adaptation BQHeat-sink access
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
B OptionB2MCB-112 PTC Therm. Card
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionD0MCB-107 24V DC backup
Frame SizeD3H
Height [mm]909,0
Height w/ Regen/Loadshare [mm]1004,0
Width w/ no C options [mm]250,0
Depth [mm]375,0
Depth with Option A/B [mm]375,0
Power 110% (NO) [KW]110
kVA147
Power Loss NO [W]2555
Power Loss NO [W]2257
Continuous Current (NO) [A]212
Intermittent Current (NO) [A]233
Continuous Current (NO) [A]190
Intermittent Current (NO) [A]209
ATEX Marking 1ATEX: II (2) G [Ex eb Gb] [Ex
ATEX Marking 2db Gb] / II (2) D [Ex tb Db]

Technical data

Motor power110 kW / 150 HP
Mains voltage380 - 480 VAC
PhaseThree-phase
Protection ratingIP20 / Chassis
Frame sizeD3H
RFI filterClass A2 (EMC C3)
Brake chopperNo
Safe Torque OffYes
Control panelGraphical LCP
PCB coatingCoated PCB
Mains optionIntegrated Fuse
Product typeFrequency converter
Continuous output current212 A
Continuous current (high line)190 A
Intermittent output current233 A
Apparent power147 kVA
Power loss2555 W
Power, normal overload110 kW
Height909 mm
Height with regen/loadshare1004 mm
Width250 mm
Depth375 mm
Depth with A/B options375 mm
Net weight62 kg
Gross weight62.3 kg
Packed volume255.9 L
EAN5715253960562
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 167F6855 are available on request. Ask for documents →

Other 110 kW / 150 HP variants in VLT HVAC Drive FC 102

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery

We only use your details to answer this request. See our privacy policy.