167F6954
Danfoss 167F6954 - iC7-Hybrid System Modules (970 A, IP00, 380-690V)
- iC7-Hybrid
- System module, liquid-cooled
- IC7-60SLGCG7-970AE00F4+AEZ3+AJFX+AKFX+ANN1 +AO20+BAPR+BDC1+BEXX+BF20+BGK1+BH25+BK05+BL25+CAV0 +DAHY
- IP00/Open Type, Frame: AR12L
- Grid converter module, GC, 380-690 V AC / 500-1500 V DC, 970 A
- EMC category: C4 category
- Control Panel 2.8 OPX20
- Standard I/O: I/O and Relay Option OC7C1
- PROFINET RT OS7PR
- Functional Safety: None, not upgradable
Model code:
IC7-60SLGCG7-970AE00F4+AEZ3+AJFX+AKFX+ANN1+AO20+BAPR+BDC1+BEXX+BF20+BGK1+BH25+BK05+BL25+CAV0+DAHY
IC7-60SLGCG7-970AE00F4+AEZ3+AJFX+AKFX+ANN1+AO20+BAPR+BDC1+BEXX+BF20+BGK1+BH25+BK05+BL25+CAV0+DAHY
Similar products
- Genuine Danfoss products
- Danfoss manufacturer warranty
- Reply within one business day
Product details
| Product series | +DAHY | iC7-Hybrid |
| Product group | IC7-60 | iC7-60 |
| Product category | SL | System module, liquid-cooled |
| Product type | GC | Grid converter module, GC |
| Mains voltage | G7 | 380-690 V AC / 500-1500 V DC |
| Current rating | -970A | 970 A |
| Power rating | XXX | Not relevant |
| Protection rating | E00 | IP00/Open Type |
| EMC category | F4 | C4 category |
| Integration unit | +AEZ3 | Standard, with LCL filter |
| Mains input device | +AJFX | AC fuses |
| DC fuses and devices | +AKFX | DC bus fuses |
| Cooling circuit connector type | +ANN1 | Push-in connection |
| Cooling circuit hose length | +AO20 | 2.0 m (6 ft) |
| Marine construction | +AFXX | None |
| Extra environmental protection | +AGCX | Coated boards |
| Communication interface, X1/X2 | +BAPR | PROFINET RT OS7PR |
| Communication interface, X0 | +BBEL | Ethernet port, no protocol |
| Standard I/O | +BDC1 | I/O and Relay Option OC7C1 |
| Functional safety | +BEXX | None, not upgradable |
| Control panel | +BF20 | Control Panel 2.8 OPX20 |
| Control panel mounting type | +BGK1 | Flush mount |
| Control panel cable length | +BH25 | 2.5 m (8 ft) |
| Control unit cable length | +BK05 | 0.5 m (1.6 ft), Fiber |
| StarCoupler board cable length | +BL25 | 2.5 m (8 ft), Fiber |
| Option slot A | +CAV0 | Voltage Measurement OC7V0 |
| Option slot B | +CBXX | None, without mounting plate |
| Option slot C | +CCXX | None, without mounting plate |
| Option slot D | +CDXX | None, without mounting plate |
| Option slot E | +CEXX | None, without mounting plate |
| Option slot F | +CFXX | None, without mounting plate |
| Option slot G | +CGXX | None, without mounting plate |
| Option slot H | +CHXX | None, without mounting plate |
| Option slot I | +CIXX | None, without mounting plate |
| Option slot J | +CJXX | None, without mounting plate |
| Language package | +EL01 | Global |
| Customer specific application | +DBXX | None |
| Additional drive features 1 | +DD1X | None |
| Additional drive features 2 | +DE2X | None |
| Additional drive features 3 | +DF3X | None |
| Additional drive features 4 | +DG4X | None |
| Additional drive features 5 | +DH5X | None |
| High speed enabled | +DI6X | No |
| Customization file package ID | +EAXXXXXX | No customization |
| Product software ID | +ECXXX | Latest released version |
| Technical documentation | +EGXX | None |
| Documentation language | +EHXX | Multi-language |
| Customer-specific label | +EJXX | None |
| Shipping package | +TACB | Cardboard box package |
| Product specific marine cert. | +VBXX | None |
| Frame designation | AR12L | |
| Main unit Width | 235mm/9.3in+300mm/11.8in | |
| Main unit Height | 1295mm/51in+429.5mm/16.9in | |
| Main unit Depth | 566mm/22.3in+249.9mm/9.8in | |
| AC voltage | 3X380-690VAC | |
| Apparent power | /1040kVA(600VAC) | |
| Apparent power | 1196kVA(690VAC) | |
| Continous current IL (1/5min) | 970A | |
| Cooling type | Liquid Cooled | |
| DC Bus current | 1156A(1025VDC) | |
| DC Bus voltage | 500-1500VDC | |
| DC power | 1184kW(1500VDC) | |
| Liquid temp. High Overload | 45°C/113°F | |
| Liquid temp. Low Overload | 45°C/113°F | |
| Liquid temp. Nominal load | 45°C/113°F | |
| Nominal AC current | 1000A | |
| Power factor | cos φ = 0 ind. to 0 cap. | |
| Storage temperature | -40...70°C/-40...158°F |
Technical data
| Mains voltage | 380-690 V AC / 500-1500 V DC | |
| Protection rating | IP00/Open Type | |
| Frame size | AR12L | |
| RFI filter | None (EMC C4) | |
| Control panel | Control Panel 2.8 (OPX20) | |
| PCB coating | Coated PCB | |
| Mains option | Integrated Fuse | |
| Fieldbus | PROFINET RT OS7PR | |
| Product type | System module, liquid-cooled (Grid converter module, GC) | |
| Continuous output current | 970 A | |
| Rated current | 970 A | |
| Apparent power | 1040 kVA | |
| Standard I/O | I/O and Relay Option OC7C1 | |
| Net weight | 304 kg | |
| Gross weight | 367 kg | |
| Packed volume | 982 L | |
| EAN | 5715253961552 | |
| ECCN (US) | 3A999.a | |
Documents