167F8921
Danfoss 167F8921 - VLT AQUA Drive FC 202 (450 kW / 600 HP, IP00, 380-480V)
- Frequency converter
- VLT® AQUA Drive FC-202
- (N450) 450 KW / 600 HP,
- Three phase, 380 - 480 VAC, (E00) IP00 / Chassis
- RFI Filter
- No brake chopper
- Graphical Loc. Cont. Panel
- Coated PCB, Loadsharing
- Condition Based Monitoring CBM
- Frame: E3H
- No A Option, MCB-114 VLT Sensor Input
- No C1 option, MCB-107 24V DC backup
Model code:
FC-202N450T4E00H2XGCDXXLX1XXAXB4CXXXXD0
FC-202N450T4E00H2XGCDXXLX1XXAXB4CXXXXD0
Similar products
- Genuine Danfoss products
- Danfoss manufacturer warranty
- Reply within one business day
Product details
| Product Group | FC- | VLT® AQUA Drive FC- |
| Series | 202 | |
| Power Rating | N450 | (N450) 450 KW / 600 HP |
| Phase | T | Three phase |
| Mains Voltage | 4 | 380 - 480 VAC |
| Enclosure | E00 | (E00) IP00 / Chassis |
| RFI Filter | H2 | RFI Filter |
| Brake - Safe Stop | X | No brake chopper |
| LCP | G | Graphical Loc. Cont. Panel |
| Coating PCB | C | Coated PCB |
| Mains Option | D | Loadsharing |
| Adaptation A | X | Standard Cable Entries |
| Adaptation B | X | No adaptation |
| Software Release | LX1X | Condition Based Monitoring CBM |
| Software Language Pack | X | Standard Language Pack |
| B Option | B4 | MCB-114 VLT Sensor Input |
| C0 Option MCO | CX | No C0 option |
| C1 Option | X | No C1 option |
| C Option Software | XX | No software option |
| D Option | D0 | MCB-107 24V DC backup |
| Frame Size | E3H | |
| Height [mm] | 1578,0 | |
| Width w/ no C options [mm] | 507,0 | |
| Depth [mm] | 482,0 | |
| Depth with Option A/B [mm] | 482,0 | |
| Power 150% (HO) [KW] | 400 | |
| Power 110% (NO) [KW] | 450 | |
| kVA | 554 | |
| Power Loss HO [W] | 7297 | |
| Power Loss HO [W] | 7240 | |
| Power Loss NO [W] | 8783 | |
| Power Loss NO [W] | 7969 | |
| Continuous Current (HO) [A] | 695 | |
| Intermittent Current (HO) [A] | 1042 | |
| Continuous Current (HO) [A] | 678 | |
| Intermittent Current (HO) [A] | 1017 | |
| Continuous Current (NO) [A] | 800 | |
| Intermittent Current (NO) [A] | 880 | |
| Continuous Current (NO) [A] | 730 | |
| Intermittent Current (NO) [A] | 803 |
Technical data
| Motor power | 450 kW / 600 HP | |
| Mains voltage | 380 - 480 VAC | |
| Phase | Three-phase | |
| Protection rating | IP00 / Chassis | |
| Frame size | E3H | |
| RFI filter | Class A2 (EMC C3) | |
| Brake chopper | No | |
| Control panel | Graphical LCP | |
| PCB coating | Coated PCB | |
| Mains option | Loadsharing | |
| Product type | Frequency converter | |
| Continuous output current | 800 A | |
| Continuous current (high line) | 730 A | |
| Intermittent output current | 880 A | |
| Continuous current (high overload) | 695 A | |
| Apparent power | 554 kVA | |
| Power loss | 8783 W | |
| Power, normal overload | 450 kW | |
| Power, high overload | 400 kW | |
| Height | 1578 mm | |
| Width | 507 mm | |
| Depth | 482 mm | |
| Depth with A/B options | 482 mm | |
| Net weight | 272 kg | |
| Gross weight | 272.3 kg | |
| Packed volume | 963.2 L | |
| EAN | 5715253983837 | |
| ECCN (US) | 3A999.a | |
Documents
Operating guides, design guides, certificates and CAD drawings for 167F8921 are available on request. Ask for documents →
Other 450 kW / 600 HP variants in VLT AQUA Drive FC 202
- 137L1637 IP20 · Class A2 · E3H
- 136U6622 IP20 · Class A2 · E3H
- 136Z9952 IP20 · Class A2 · E3H
- 135U3667 IP20 · Class A2 · E3H
- 135U2463 IP20 · Class A2 · E3H
- 137N0318 IP20 · Class A1 · E3H
- 137X6401 IP21 · Class A2 · E1H
- 132X0414 IP21 · Class A2 · E1H
- 136L0674 IP54 · Class A2 · E1H
- 136L0660 IP54 · Class A2 · E1H
- 136L0658 IP54 · Class A2 · E1H
- 167G4649 IP54 · Class A2 · E1H
- 135X0608 IP54 · Class A2 · E1H
- 167G2264 IP54 · Class A1 · E1H
- 135U7627 IP54 · Class A1 · E1H
- 137L0905 IP54 · Class A2 · E1H
- 137X7779 IP54 · Class A2 · E1H
- 137X5578 IP54 · Class A2 · E1H
- 136L0672 IP54 · Class A2 · E1H
- 137L4035 IP54 · Class A2 · E1H
- 136U9883 IP54 · Class A2 · E1H
- 136N2614 IP54 · Class A2 · E1H
- 137L1612 IP54 · Class A2 · E1H
- 167F4299 IP54 · Class A1 · E1H