Danfoss VLT HVAC Drive FC 102 FC-102P4K0T4E20H2TGXXXXLX1XXAXB0CXRXXD0
167F9689

Danfoss 167F9689 - VLT HVAC Drive FC 102 (4 kW / 5 HP, IP20, 380-480V)

  • Frequency Converter
  • VLT® HVAC Drive FC-102
  • (P4K0) 4.0 KW / 5.0 HP,
  • Three phase, 380 - 480 VAC, (E20) IP20 / Chassis
  • RFI Filter
  • Safe Stop
  • Graphical Loc. Cont. Panel
  • Not coated PCB, No Mains Option
  • Condition Based Monitoring CBM
  • Frame: A2
  • No A Option, MCB-109 I/O, RTC Back-up
  • MCB-113 Ext. Relay Card, MCB-107 24V DC backup
Model code:
FC-102P4K0T4E20H2TGXXXXLX1XXAXB0CXRXXD0
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® HVAC Drive FC-
Series102
Power RatingP4K0(P4K0) 4.0 KW / 5.0 HP
PhaseTThree phase
Mains Voltage4380 - 480 VAC
EnclosureE20(E20) IP20 / Chassis
RFI FilterH2RFI Filter
Brake - Safe StopTSafe Stop
LCPGGraphical Loc. Cont. Panel
Coating PCBXNot coated PCB
Mains OptionXNo Mains Option
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseLX1XCondition Based Monitoring CBM
Software Language PackXStandard Language Pack
B OptionB0MCB-109 I/O, RTC Back-up
C0 Option MCOCXNo C0 option
C1 OptionRMCB-113 Ext. Relay Card
C Option SoftwareXXNo software option
D OptionD0MCB-107 24V DC backup
Frame SizeA2
Height [mm]268,0
Width w/ no C options [mm]90,0
Width w/ two C options [mm]150,0
Depth [mm]205,0
Depth with Option A/B [mm]220,0
Power 110% (NO) [KW]4
kVA6.93
Power Loss NO [W]124
Continuous Current (NO) [A]10
Intermittent Current (NO) [A]11
Continuous Current (NO) [A]8.2
Intermittent Current (NO) [A]9.02

Technical data

Motor power4 kW / 5 HP
Mains voltage380 - 480 VAC
PhaseThree-phase
Protection ratingIP20 / Chassis
Frame sizeA2
RFI filterClass A2 (EMC C3)
Brake chopperNo
Safe Torque OffYes
Control panelGraphical LCP
PCB coatingUncoated
Mains optionNone
Product typeFrequency converter
Continuous output current10 A
Continuous current (high line)8.2 A
Intermittent output current11 A
Apparent power6.93 kVA
Power loss124 W
Power, normal overload4 kW
Height268 mm
Width90 mm
Width with C options150 mm
Depth205 mm
Depth with A/B options220 mm
Net weight5.3 kg
Gross weight6.146 kg
Packed volume27.2 L
EAN5715786013070
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 167F9689 are available on request. Ask for documents →

Other 4 kW / 5 HP variants in VLT HVAC Drive FC 102

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery

We only use your details to answer this request. See our privacy policy.