Danfoss VLT AutomationDrive FC 302 FC-302P55KT5E66H2BGX1XXSXXXXANB2CXXXXDX
167G4239

Danfoss 167G4239 - VLT AutomationDrive FC 302 (55 kW / 75 HP, IP66, 380-500V)

  • Frequency converter
  • VLT® AutomationDrive FC-302
  • (P55K) 55 KW / 75 HP,
  • Three phase, 380 - 500 VAC, (E66) IP66 / NEMA 4X
  • RFI Filter
  • Brake chopper
  • Graphical Loc. Cont. Panel
  • Not coated PCB, Mains Disconnect
  • Latest release std. SW.
  • Frame: C2
  • EtherNet/IP MCA 121, MCB-112 PTC Therm. Card
  • No C1 option, No D option
  • ATEX: II (2) G [Ex eb Gb] [Ex db Gb] / II (2) D [Ex tb Db]
Model code:
FC-302P55KT5E66H2BGX1XXSXXXXANB2CXXXXDX
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® AutomationDrive FC-
Series302
Power RatingP55K(P55K) 55 KW / 75 HP
PhaseTThree phase
Mains Voltage5380 - 500 VAC
EnclosureE66(E66) IP66 / NEMA 4X
RFI FilterH2RFI Filter
Brake - Safe StopBBrake chopper
LCPGGraphical Loc. Cont. Panel
Coating PCBXNot coated PCB
Mains Option1Mains Disconnect
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
B OptionB2MCB-112 PTC Therm. Card
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionDXNo D option
Frame SizeC2
Power 150% (HO) [KW]55
Power 110% (NO) [KW]75
Power Loss HO [W]1022
Power Loss NO [W]1384
kVA73.4
Continuous Current (HO) [A]106
Intermittent Current (HO) [A]159
Continuous Current (HO) [A]105
Continuous Current (NO) [A]130
Intermittent Current (HO) [A]158
Intermittent Current (NO) [A]162
Continuous Current (NO) [A]147
Intermittent Current (NO) [A]143
Height [mm]780,0
Width w/ no C options [mm]370,0
Depth [mm]332,0
Depth with Option A/B [mm]332,0
ATEX Marking 1ATEX: II (2) G [Ex eb Gb] [Ex
ATEX Marking 2db Gb] / II (2) D [Ex tb Db]

Technical data

Motor power55 kW / 75 HP
Mains voltage380 - 500 VAC
PhaseThree-phase
Protection ratingIP66 / NEMA 4X
Frame sizeC2
RFI filterClass A2 (EMC C3)
Brake chopperYes
Safe Torque OffYes
Control panelGraphical LCP
PCB coatingUncoated
Mains optionMains Disconnect
Product typeFrequency converter
Continuous output current130 A
Continuous current (high line)147 A
Intermittent output current162 A
Continuous current (high overload)106 A
Apparent power73.4 kVA
Power loss1384 W
Power, normal overload75 kW
Power, high overload55 kW
Height780 mm
Width370 mm
Depth332 mm
Depth with A/B options332 mm
Net weight55.36 kg
Gross weight58.7 kg
Packed volume207.4 L
EAN5715786041295
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 167G4239 are available on request. Ask for documents →

Other 55 kW / 75 HP variants in VLT AutomationDrive FC 302

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery