Danfoss VLT HVAC Drive FC 102 FC-102P800T4L2XHERGCJKGSXXXXA4B4CXXXXDX
131U4891

Danfoss 131U4891 - VLT HVAC Drive FC 102 (800 kW / 1200 HP, IP21, 380-480V)

  • Frequency Converter
  • NB: F-frame platform available until December 31, 2025
  • VLT® HVAC Drive FC-102
  • (P800) 800 KW / 1200 HP,
  • Three phase, 380 - 480 VAC,IP21+ Cab Light-IEC 230V
  • RCD TN/TT Mains+ A2 RFI
  • Regen Terminals
  • Graphical Loc. Cont. Panel
  • Coated PCB, Circuit Breaker + Fuse
  • Latest release std. SW.
  • Frame: F4
  • DeviceNet MCA 104, MCB-114 VLT Sensor Input
  • No C1 option, No D option
Model code:
FC-102P800T4L2XHERGCJKGSXXXXA4B4CXXXXDX
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® HVAC Drive FC-
Series102
Power RatingP800(P800) 800 KW / 1200 HP
PhaseTThree phase
Mains Voltage4380 - 480 VAC
EnclosureL2XIP21+ Cab Light-IEC 230V
RFI FilterHERCD TN/TT Mains+ A2 RFI
Brake - Safe StopRRegen Terminals
LCPGGraphical Loc. Cont. Panel
Coating PCBCCoated PCB
Mains OptionJCircuit Breaker + Fuse
Adaptation AKTwo 2.5-4A man motor star
Adaptation BG5A 24V PS+Ext Temp Monitor
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionA4DeviceNet MCA 104
B OptionB4MCB-114 VLT Sensor Input
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionDXNo D option
Frame SizeF4
Power 110% (NO) [KW]800
Height [mm]2204,0
Width w/ no C options [mm]2400,0
Depth [mm]606,0
Depth with Option A/B [mm]606,0
kVA1012
Power Loss NO [W]17293
Power Loss NO [W]16229
Continuous Current (NO) [A]1460
Intermittent Current (NO) [A]1606
Continuous Current (NO) [A]1380
Intermittent Current (NO) [A]1518

Technical data

Motor power800 kW / 1200 HP
Mains voltage380 - 480 VAC
PhaseThree-phase
Protection ratingIP21+ Cab Light-IEC 230V
Frame sizeF4
RFI filterClass A2 (EMC C3)
Brake chopperNo
Control panelGraphical LCP
PCB coatingCoated PCB
Mains optionCircuit Breaker + Fuse
FieldbusDeviceNet MCA 104
Product typeFrequency converter
Continuous output current1460 A
Continuous current (high line)1380 A
Intermittent output current1606 A
Apparent power1012 kVA
Power loss17293 W
Power, normal overload800 kW
Height2204 mm
Width2400 mm
Depth606 mm
Depth with A/B options606 mm
Net weight1037 kg
Gross weight1037.3 kg
EAN5702427962347
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 131U4891 are available on request. Ask for documents →

Other 800 kW / 1200 HP variants in VLT HVAC Drive FC 102

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery

We only use your details to answer this request. See our privacy policy.