Danfoss VLT HVAC Drive FC 102 FC-102N800T7E54H2TGC7XXSXXXXAXBXCXXXXDX
135U4015

Danfoss 135U4015 - VLT HVAC Drive FC 102 (800 kW / 1200 HP, IP54, 525-690V)

  • Frequency Converter
  • VLT® HVAC Drive FC-102
  • (N800) 800 KW / 1200 HP, Specific Ratings: 670kW@525-550V, 950HP@575V, 800kW@690V
  • Three phase, 525 - 690 VAC *,(E54) IP54 / Type 12
  • RFI Filter
  • Safe Stop
  • Graphical Loc. Cont. Panel
  • Coated PCB, Fuse
  • Latest release std. SW.
  • Frame: E2H
  • No A Option, No B Option
  • No C1 option, No D option
Model code:
FC-102N800T7E54H2TGC7XXSXXXXAXBXCXXXXDX
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® HVAC Drive FC-
Series102
Power RatingN800(N800) 800 KW / 1200 HP
PhaseTThree phase
Mains Voltage7525 - 690 VAC *
EnclosureE54(E54) IP54 / Type 12
RFI FilterH2RFI Filter
Brake - Safe StopTSafe Stop
LCPGGraphical Loc. Cont. Panel
Coating PCBCCoated PCB
Mains Option7Fuse
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionAXNo A Option
B OptionBXNo B Option
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionDXNo D option
Frame SizeE2H
Power 110% (NO) [KW]800
Height [mm]2000,0
Width w/ no C options [mm]700,0
Depth [mm]510,0
Depth with Option A/B [mm]510,0
kVA1016
Power Loss NO [W]12723
Power Loss NO [W]12321
Continuous Current (NO) [A]889
Intermittent Current (NO) [A]978
Continuous Current (NO) [A]850
Intermittent Current (NO) [A]935
Power Rating at 525-550V670kW
Power Rating at 575V950HP
Power Rating at 690V800kW

Technical data

Motor power800 kW / 1200 HP
Mains voltage525 - 690 VAC *
PhaseThree-phase
Protection ratingIP54 / Type 12
Frame sizeE2H
RFI filterClass A2 (EMC C3)
Brake chopperNo
Safe Torque OffYes
Control panelGraphical LCP
PCB coatingCoated PCB
Mains optionIntegrated Fuse
FieldbusNone
Product typeFrequency converter
Continuous output current889 A
Continuous current (high line)850 A
Intermittent output current978 A
Apparent power1016 kVA
Power loss12723 W
Power, normal overload800 kW
Height2000 mm
Width700 mm
Depth510 mm
Depth with A/B options510 mm
Net weight318 kg
Gross weight318.3 kg
EAN5710108302719
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 135U4015 are available on request. Ask for documents →

Other 800 kW / 1200 HP variants in VLT HVAC Drive FC 102

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty

We only use your details to answer this request. See our privacy policy.