Danfoss VLT HVAC Drive FC 102 FC-102P800T4E54H2BGCXXKSXXXXALBXCXXXXDX
136F8256

Danfoss 136F8256 - VLT HVAC Drive FC 102 (800 kW / 1200 HP, IP54, 380-480V)

  • Frequency Converter
  • NB: F-frame platform available until December 31, 2025
  • VLT® HVAC Drive FC-102
  • (P800) 800 KW / 1200 HP,
  • Three phase, 380 - 480 VAC,(E54) IP54 / Type 12
  • RFI Filter
  • Brake chopper
  • Graphical Loc. Cont. Panel
  • Coated PCB, No Mains Option
  • Latest release std. SW.
  • Frame: F2
  • PROFINET MCA 120, No B Option
  • No C1 option, No D option
Model code:
FC-102P800T4E54H2BGCXXKSXXXXALBXCXXXXDX
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® HVAC Drive FC-
Series102
Power RatingP800(P800) 800 KW / 1200 HP
PhaseTThree phase
Mains Voltage4380 - 480 VAC
EnclosureE54(E54) IP54 / Type 12
RFI FilterH2RFI Filter
Brake - Safe StopBBrake chopper
LCPGGraphical Loc. Cont. Panel
Coating PCBCCoated PCB
Mains OptionXNo Mains Option
Adaptation AXStandard Cable Entries
Adaptation BKF Frame Common Motor Term
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionALPROFINET MCA 120
B OptionBXNo B Option
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionDXNo D option
Frame SizeF2
Power 110% (NO) [KW]800
Height [mm]2204,0
Width w/ no C options [mm]1800,0
Depth [mm]606,0
Depth with Option A/B [mm]606,0
kVA1012
Power Loss NO [W]17293
Power Loss NO [W]16229
Continuous Current (NO) [A]1460
Intermittent Current (NO) [A]1606
Continuous Current (NO) [A]1380
Intermittent Current (NO) [A]1518

Technical data

Motor power800 kW / 1200 HP
Mains voltage380 - 480 VAC
PhaseThree-phase
Protection ratingIP54 / Type 12
Frame sizeF2
RFI filterClass A2 (EMC C3)
Brake chopperYes
Control panelGraphical LCP
PCB coatingCoated PCB
Mains optionNone
FieldbusPROFINET MCA 120
Product typeFrequency converter
Continuous output current1460 A
Continuous current (high line)1380 A
Intermittent output current1606 A
Apparent power1012 kVA
Power loss17293 W
Power, normal overload800 kW
Height2204 mm
Width1800 mm
Depth606 mm
Depth with A/B options606 mm
Net weight1260 kg
Gross weight1260.3 kg
EAN5710108546915
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 136F8256 are available on request. Ask for documents →

Other 800 kW / 1200 HP variants in VLT HVAC Drive FC 102

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery