136N7264
Danfoss 136N7264 - VLT HVAC Drive FC 102 (315 kW / 450 HP, IP00, 380-480V)
- Frequency Converter
- VLT® HVAC Drive FC-102
- (N315) 315 KW / 450 HP, Three phase
- 380 - 480 VAC, (E00) IP00 / Chassis
- Parallel 12 Pulse + A1
- No brake chopper
- Graphical Loc. Cont. Panel
- Coated PCB, Fuse
- Latest release std. SW.
- Frame: DB2
- No C1 option, No D option
- No A Option, No B Option
Model code:
FC-102N315T4E00P8XGC7XXSXXXXAXBXCXXXXDX
FC-102N315T4E00P8XGC7XXSXXXXAXBXCXXXXDX
Similar products
- Genuine Danfoss products
- Danfoss manufacturer warranty
- Reply within one business day
Product details
| Product Group | FC- | VLT® HVAC Drive FC- |
| Series | 102 | |
| Power Rating | N315 | (N315) 315 KW / 450 HP |
| Phase | T | Three phase |
| Mains Voltage | 4 | 380 - 480 VAC |
| Enclosure | E00 | (E00) IP00 / Chassis |
| RFI Filter | P8 | Parallel 12 Pulse + A1 |
| Brake - Safe Stop | X | No brake chopper |
| LCP | G | Graphical Loc. Cont. Panel |
| Coating PCB | C | Coated PCB |
| Mains Option | 7 | Fuse |
| Adaptation A | X | Standard Cable Entries |
| Adaptation B | X | No adaptation |
| Software Release | SXXX | Latest release std. SW. |
| Software Language Pack | X | Standard Language Pack |
| A Option | AX | No A Option |
| B Option | BX | No B Option |
| C0 Option MCO | CX | No C0 option |
| C1 Option | X | No C1 option |
| C Option Software | XX | No software option |
| D Option | DX | No D option |
| Frame Size | DB2 | |
| Power 110% (NO) [KW] | 315 | |
| Height [mm] | 1122,0 | |
| Width w/ no C options [mm] | 700,0 | |
| Depth [mm] | 375,0 | |
| Depth with Option A/B [mm] | 375,0 | |
| kVA | 407 | |
| Power Loss NO [W] | 6663 | |
| Power Loss NO [W] | 5703 | |
| Continuous Current (NO) [A] | 588 | |
| Intermittent Current (NO) [A] | 647 | |
| Continuous Current (NO) [A] | 535 | |
| Intermittent Current (NO) [A] | 588 |
Technical data
| Motor power | 315 kW / 450 HP | |
| Mains voltage | 380 - 480 VAC | |
| Phase | Three-phase | |
| Protection rating | IP00 / Chassis | |
| Frame size | DB2 | |
| RFI filter | Class A1 (EMC C2) | |
| Brake chopper | No | |
| Control panel | Graphical LCP | |
| PCB coating | Coated PCB | |
| Mains option | Integrated Fuse | |
| Fieldbus | None | |
| Product type | Frequency converter | |
| Continuous output current | 588 A | |
| Continuous current (high line) | 535 A | |
| Intermittent output current | 647 A | |
| Apparent power | 407 kVA | |
| Power loss | 6663 W | |
| Power, normal overload | 315 kW | |
| Height | 1122 mm | |
| Width | 700 mm | |
| Depth | 375 mm | |
| Depth with A/B options | 375 mm | |
| Net weight | 250 kg | |
| Gross weight | 250.3 kg | |
| Packed volume | 0 L | |
| EAN | 5710108951221 | |
| ECCN (US) | 3A999 | |
Documents
Operating guides, design guides, certificates and CAD drawings for 136N7264 are available on request. Ask for documents →
Other 315 kW / 450 HP variants in VLT HVAC Drive FC 102
- 132L0604 IP00 · Class A2 · DB2
- 132X3377 IP00 · Class A2 · DB2
- 134X6433 IP00 · Class A2 · DB2
- 134X8169 IP00 · Class A1 · DB2
- 136X4789 IP20 · Class A2 · D4H
- 134L3946 IP20 · Class A2 · D4H
- 167F9009 IP20 · Class A2 · D4H
- 136Z7897 IP20 · Class A2 · D4H
- 134L2752 IP20 · Class A2 · D4H
- 134L5603 IP20 · Class A2 · D4H
- 134L3705 IP20 · Class A1 · D4H
- 135U8572 IP20 · Class A1 · D4H
- 134L5575 IP20 · Class A1 · D4H
- 134U8148 IP20 · Class A2 · D4H
- 137N9783 IP20 · Class A2 · D4H
- 135X3860 IP20 · Class A2 · D4H
- 136F8223 IP20 · Class A2 · D4H
- 132L1614 IP20 · Class A2 · D4H
- 137L9999 IP20 · Class A2 · D4H
- 136X3857 IP20 · Class A2 · D4H
- 134F6018 IP20 · Class A2 · D4H
- 134G5434 IP20 · Class A2 · D4H
- 167F8835 IP20 · Class A2 · D4H
- 167F2165 IP20 · Class A2 · D4H