Danfoss VLT HVAC Drive FC 102 FC-102N315T4E20H2TGC7XQLX1XXAXBXCXXXXDX
167F8835

Danfoss 167F8835 - VLT HVAC Drive FC 102 (315 kW / 450 HP, IP20, 380-480V)

  • Frequency Converter
  • VLT® HVAC Drive FC-102
  • (N315) 315 KW / 450 HP,
  • Three phase, 380 - 480 VAC, (E20) IP20 / Chassis
  • RFI Filter
  • Safe Stop
  • Graphical Loc. Cont. Panel
  • Coated PCB, Fuse
  • Condition Based Monitoring CBM
  • Frame: D4H
  • No A Option, No B Option
  • No C1 option, No D option
Model code:
FC-102N315T4E20H2TGC7XQLX1XXAXBXCXXXXDX
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® HVAC Drive FC-
Series102
Power RatingN315(N315) 315 KW / 450 HP
PhaseTThree phase
Mains Voltage4380 - 480 VAC
EnclosureE20(E20) IP20 / Chassis
RFI FilterH2RFI Filter
Brake - Safe StopTSafe Stop
LCPGGraphical Loc. Cont. Panel
Coating PCBCCoated PCB
Mains Option7Fuse
Adaptation AXStandard Cable Entries
Adaptation BQHeat-sink access
Software ReleaseLX1XCondition Based Monitoring CBM
Software Language PackXStandard Language Pack
B OptionBXNo B Option
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionDXNo D option
Frame SizeD4H
Height [mm]1122,0
Height w/ Regen/Loadshare [mm]1268,0
Width w/ no C options [mm]350,0
Depth [mm]375,0
Depth with Option A/B [mm]375,0
Power 110% (NO) [KW]315
kVA407
Power Loss NO [W]6663
Power Loss NO [W]5703
Continuous Current (NO) [A]588
Intermittent Current (NO) [A]647
Continuous Current (NO) [A]535
Intermittent Current (NO) [A]588

Technical data

Motor power315 kW / 450 HP
Mains voltage380 - 480 VAC
PhaseThree-phase
Protection ratingIP20 / Chassis
Frame sizeD4H
RFI filterClass A2 (EMC C3)
Brake chopperNo
Safe Torque OffYes
Control panelGraphical LCP
PCB coatingCoated PCB
Mains optionIntegrated Fuse
Product typeFrequency converter
Continuous output current588 A
Continuous current (high line)535 A
Intermittent output current647 A
Apparent power407 kVA
Power loss6663 W
Power, normal overload315 kW
Height1122 mm
Height with regen/loadshare1268 mm
Width350 mm
Depth375 mm
Depth with A/B options375 mm
Net weight125 kg
Gross weight125.3 kg
Packed volume370.2 L
EAN5715253982892
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 167F8835 are available on request. Ask for documents →

Other 315 kW / 450 HP variants in VLT HVAC Drive FC 102

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery

We only use your details to answer this request. See our privacy policy.