Danfoss VLT HVAC Drive FC 102 FC-102N315T4E20H4TGCXXXLX1XXANBXCXXXXD0
137X4881

Danfoss 137X4881 - VLT HVAC Drive FC 102 (315 kW / 450 HP, IP20, 380-480V)

  • Frequency Converter
  • VLT® HVAC Drive FC-102
  • (N315) 315 KW / 450 HP,
  • Three phase, 380 - 480 VAC, (E20) IP20 / Chassis
  • RFI class A1 (C2)
  • Safe Stop
  • Graphical Loc. Cont. Panel
  • Coated PCB, No Mains Option
  • Condition Based Monitoring CBM
  • Frame: D4H
  • EtherNet/IP MCA 121, No B Option
  • No C1 option, MCB-107 24V DC backup
Model code:
FC-102N315T4E20H4TGCXXXLX1XXANBXCXXXXD0
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® HVAC Drive FC-
Series102
Power RatingN315(N315) 315 KW / 450 HP
PhaseTThree phase
Mains Voltage4380 - 480 VAC
EnclosureE20(E20) IP20 / Chassis
RFI FilterH4RFI class A1 (C2)
Brake - Safe StopTSafe Stop
LCPGGraphical Loc. Cont. Panel
Coating PCBCCoated PCB
Mains OptionXNo Mains Option
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseLX1XCondition Based Monitoring CBM
Software Language PackXStandard Language Pack
B OptionBXNo B Option
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionD0MCB-107 24V DC backup
Frame SizeD4H
Height [mm]1122,0
Height w/ Regen/Loadshare [mm]1268,0
Width w/ no C options [mm]350,0
Depth [mm]375,0
Depth with Option A/B [mm]375,0
Power 110% (NO) [KW]315
kVA407
Power Loss NO [W]6663
Power Loss NO [W]5703
Continuous Current (NO) [A]588
Intermittent Current (NO) [A]647
Continuous Current (NO) [A]535
Intermittent Current (NO) [A]588

Technical data

Motor power315 kW / 450 HP
Mains voltage380 - 480 VAC
PhaseThree-phase
Protection ratingIP20 / Chassis
Frame sizeD4H
RFI filterClass A1 (EMC C2)
Brake chopperNo
Safe Torque OffYes
Control panelGraphical LCP
PCB coatingCoated PCB
Mains optionNone
Product typeFrequency converter
Continuous output current588 A
Continuous current (high line)535 A
Intermittent output current647 A
Apparent power407 kVA
Power loss6663 W
Power, normal overload315 kW
Height1122 mm
Height with regen/loadshare1268 mm
Width350 mm
Depth375 mm
Depth with A/B options375 mm
Net weight125 kg
Gross weight125.3 kg
Packed volume370.2 L
EAN5715253835716
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 137X4881 are available on request. Ask for documents →

Other 315 kW / 450 HP variants in VLT HVAC Drive FC 102

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty

We only use your details to answer this request. See our privacy policy.