Danfoss VLT HVAC Drive FC 102 FC-102N315T4E2MH2BGC3XXSXXXXALBXCXXXXDX
167G1863

Danfoss 167G1863 - VLT HVAC Drive FC 102 (315 kW / 450 HP, IP21, 380-480V)

  • Frequency Converter
  • VLT® HVAC Drive FC-102
  • (N315) 315 KW / 450 HP,
  • Three phase, 380 - 480 VAC, IP21/Type 1+mains shield
  • RFI Filter
  • Brake chopper
  • Graphical Loc. Cont. Panel
  • Coated PCB, Mains Disconnect + Fuse
  • Latest release std. SW.
  • Frame: D7H
  • PROFINET MCA 120, No B Option
  • No C1 option, No D option
Model code:
FC-102N315T4E2MH2BGC3XXSXXXXALBXCXXXXDX
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® HVAC Drive FC-
Series102
Power RatingN315(N315) 315 KW / 450 HP
PhaseTThree phase
Mains Voltage4380 - 480 VAC
EnclosureE2MIP21/Type 1+mains shield
RFI FilterH2RFI Filter
Brake - Safe StopBBrake chopper
LCPGGraphical Loc. Cont. Panel
Coating PCBCCoated PCB
Mains Option3Mains Disconnect + Fuse
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
B OptionBXNo B Option
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionDXNo D option
Frame SizeD7H
Height [mm]1978,0
Width w/ no C options [mm]420,0
Depth [mm]386,0
Depth with Option A/B [mm]386,0
Power 110% (NO) [KW]315
kVA407
Power Loss NO [W]6663
Power Loss NO [W]5703
Continuous Current (NO) [A]588
Intermittent Current (NO) [A]647
Continuous Current (NO) [A]535
Intermittent Current (NO) [A]588

Technical data

Motor power315 kW / 450 HP
Mains voltage380 - 480 VAC
PhaseThree-phase
Protection ratingIP21/Type 1+mains shield
Frame sizeD7H
RFI filterClass A2 (EMC C3)
Brake chopperYes
Control panelGraphical LCP
PCB coatingCoated PCB
Mains optionMains Disconnect + Fuse
Product typeFrequency converter
Continuous output current588 A
Continuous current (high line)535 A
Intermittent output current647 A
Apparent power407 kVA
Power loss6663 W
Power, normal overload315 kW
Height1978 mm
Width420 mm
Depth386 mm
Depth with A/B options386 mm
Net weight200 kg
Gross weight200.3 kg
Packed volume956.2 L
EAN5715786017078
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 167G1863 are available on request. Ask for documents →

Other 315 kW / 450 HP variants in VLT HVAC Drive FC 102

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery

We only use your details to answer this request. See our privacy policy.